2.4 Tray1 separation roller

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
1. Remove the tray1 separation roller unit.
F.5.4.4 Replacing the tray1 separation roller
[1]

2.5 Tray2 separation roller

NOTE
• The alcohol described in the cleaning procedure represents the isopropyl alcohol.
1. Pull out tray2.
[3]
[1]
[2]
[1]

2.6 Laser irradiation section

1. Slide out tray1.
[1]
H CLEANING/LUBRICATION > 2. Cleaning procedure
2. Using a cleaning pad dampened with alcohol, wipe the tray1
separation roller [1] clean of dirt.
2. Remove the C-ring [1] and the bearing [2], and remove the tray2
feed roller unit [3].
3. Using a cleaning pad dampened with alcohol, wipe the tray2
separation roller [1] clean of dirt.
2. Remove the cover [1].