D3F1 - Konica Minolta BIZHUB C3100P Service Manual

Hide thumbs Also See for BIZHUB C3100P:
Table of Contents

Advertisement

3.4.28 D3F1

(1) Contents
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
This code is displayed when the counter backup
process is completed successfully. When this code is
1
displayed, turn OFF/ON the power switch and then
perform the given steps.
3.4.29 D3F4
(1) Contents
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
1
Reboot the main body.
Check the MFPB connector for proper connection and
2
correct as necessary.
3
Replace MFPB.
After taking the above actions, if the counter backup
process results in the same trouble code again, the
4
EEPROM can be broken. In this case, the counter
backup is unavailable.
• Link to the layout drawings for related parts by each trouble code
Successful completion of counter backup
D3F1
The counter backup process is completed successfully.
-
-
Action
G.5.10 MFP board (MFPB)
Abnormal end of counter backup
D3F4
The counter backup process results in an abnormal end due to a write error or other reasons.
-
MFP board (MFPB)
Action
K TROUBLESHOOTING > 3. TROUBLE CODE
Control signal
-
Control signal
-
-
-
-
(S.19. C013, C015, C025, C026, C027, C060, D3A2,
K-23
Location of electrical components
-
Location of electrical components
-
-
-
-
D3F4)