C050; C051 - Konica Minolta BIZHUB C3100P Service Manual

Hide thumbs Also See for BIZHUB C3100P:
Table of Contents

Advertisement

Trouble isolation
Relevant electrical parts
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
1
Reboot the main body.
Check the MFPB connector for proper connection and
2
correct as necessary.
If this error message is displayed after update of
3
firmware, conduct the firmware update procedures
again.
4
Replace MFPB.
• Link to the layout drawings for related parts by each trouble code

3.4.23 C050

(1) Contents
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
1
Reboot the main body.
Check the HD-P06 connector for proper connection
2
and correct as necessary.
Check the MFPB connector for proper connection and
3
correct as necessary.
4
Replace HD-P06.
5
Replace MFPB.
• Link to the layout drawings for related parts by each trouble code

3.4.24 C051

(1) Contents
Trouble type
Trouble code
Detection timing
Trouble isolation
Relevant electrical parts
(2) Procedure
Step
1
Reboot the main body.
Delete the job hold in [PROOF/PRINT MENU] to
2
increase the available range for user space.
Check the HD-P06 connector for proper connection
3
and correct as necessary.
Format HD-P06 with [ADMIN SETTINGS] - [SYSTEM
4
SETTINGS] -> [SECURITY SETTINGS] -> [HDD
SETTINGS] -> [HDD FORMAT].
5
Replace HD-P06.
6
Replace MFPB.
-
MFP board (MFPB)
Controller ROM error (Data error)
C027
Final check sum error is detected during the printer starting.
-
MFP board (MFPB)
Action
HDD access error
C050
When correct access to the hard disk kit is failed during access.
-
• MFP board (MFPB)
• Hard disk kit (HD-P06)
Action
HDD full error
C051
Range for user space is full during access to the hard disk kit.
-
• MFP board (MFPB)
• Hard disk kit (HD-P06)
Action
K TROUBLESHOOTING > 3. TROUBLE CODE
Control signal
-
-
-
-
(S.19. C013, C015, C025, C026, C027, C060, D3A2,
Control signal
-
-
-
-
-
(S.20. C050,
C051)
Control signal
-
-
-
-
-
-
K-21
Location of electrical components
-
-
-
-
D3F4)
Location of electrical components
-
-
-
-
-
Location of electrical components
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents