Simple Connection of the
MKS-8080/8082 AUX Bus
Remote Panel

Procedure for Simple Connection

To connect the MKS-8080/8082 AUX Bus Remote Panel
to the center control panel using an S-Bus data link
requires a BKPF-R70A Routing Switcher Controller
Board or similar primary station and various settings for
connection.
However, using a simple connection, the need for an S-Bus
data link primary station is avoided, and direct connection
to the MKS-8080/8082 is possible.
A simple connection is possible if the following conditions
are met:
• There are no devices other than the center control panel
and MKS-8080/8082 connected on the S-Bus data link.
• There are no more than 16 MKS-8080/8082 units
connected on the S-Bus data link.
To carry out simple connection of the MKS-8080/8082
AUX Bus Remote Panel, use the following procedure.
For settings on the MKS-8080/8082, see the section
"Making the Setting With Buttons (Setup Function)" in the
Operation Manual for the MKS-8080/8082.
1
Carry out initialization of the MKS-8080/8082
settings.
This can be done on the MKS-8080/8082 separately.
2
Set the MKS-8080/8082 station number in the range 2
to 17.
This can be done on the MKS-8080/8082 separately.
3
Set the S-Bus data link primary station to the center
control panel by setting the STATION ID switches on
the front of the board in the SCU SLOT 1 to 001
(switch 1 only to the OPEN position).
664

Simple Connection of the MKS-8080/8082 AUX Bus Remote Panel

System control unit Board
MKS-8010A
FP-141 S108
MKS-8010B
CA-76
4
In the Engineering Setup >System >Initialize menu,
select PNL, and carry out a reset.
This carries out a restart, and when the restart is
completed connection to the MKS-8080/8082 is
possible.
5
In the Engineering Setup >Router/Tally >Router
menu, set the position of the MVS-8000X/7000X
system in S-Bus space.
Select the setting from SWR1 and SWR2, and set each
of Source, Destination, and Level to 1.
Setting Status of the MKS-8080/8082
in Simple Connection
As a result of making the simple connection, the MKS-
8080/8082 operates in AUX bus mode, and the settings are
the following factory defaults.
With regard to the meaning of the following settings, see
the section "Menu Operations" in the Operation Manual
for the MKS-8080/8082.
C: SET SWITCHER ID (for AUX mode)
This is set to 001, which is the station number of the center
control panel.
D: SET AUX DESTINATION/SOURCE (for AUX
mode)
The source is set to IN001 and following, and destination
is set to OUT001 and following.
H: SET PHANTOM TABLE (for Router mode)
This is not set, since the unit does not operate in router
mode.
STATION ID switches
S9108

Advertisement

Table of Contents
loading

Table of Contents