Copying Cross-Point Assign Tables - Sony MVS-8000X SystemMVS-7000X System User Manual

Multi format switcher system with ccp-8000 series center control panel
Table of Contents

Advertisement

In the <Xpt Shift Mode> group of the Panel >Xpt Assign
>Main, V/K Pair Assign menu or Panel >Xpt Assign
>Table Button Assign menu, select one of the following
for each cross-point table.
Hold: Acts as a shift button, and the shifted version of the
cross-point buttons is enabled while the button is held
down.
Lock: Acts as a shift button, and pressing the button
toggles between the shifted version and the unshifted
version.
Off: Acts as a cross-point button, in a 16-button system as
button number 16, in a 24-button system as button
number 24, and in a 32-button system as button
number 32.
Setting the action of the [SHIFT] button in
the cross-point control block
In the <Display Shift Mode> group of the Panel >Xpt
Assign >Main, V/K Pair Assign menu or Panel >Xpt
Assign >Table Button Assign menu, select either of the
following.
Shift All Bus: When this is On, it functions as a shift
button for all buses.
Key5-8 Select: This functions as a shift button dedicated
to the key 1 and key 2 rows. When On, keys 5 to 8 are
selected, and when Off, keys 1 to 4 are selected.
Notes
• It is not possible to make this setting separately for each
of the M/E and PGM/PST banks.
• "Shift All Bus" is only valid when the cross-point button
shift operation (see previous item) is set to "Lock" or
"Off."
• If both "Shift All Bus" and "Key5-8 Select" are off, the
[SHIFT] button functions as a shift button for the source
name display. It is not possible to set both "Shift All
Bus" and "Key5-8 Select" to On.
Setting the source signal name
1
In the Panel >Xpt Assign menu or Panel >Xpt Assign
>Table Button Assign menu, press [Src Name/LCD
Color].
The Src Name/LCD Color menu appears.
2
Turn the knob to select the signal to be set.
Knob Parameter Adjustment
1
Source No Source signal
selection
2
Num
Number of
source signals to
be selected
3
Press [Source Name].
A keyboard window appears.
4
Enter any name of not more than 16 characters, then
press [Enter].
Sequential names for multiple signals
When you specify a number at the end of a signal name, all
of the signals in the range selected by knobs 1 and 2 are
automatically assigned names ending with sequential
numbers.
Example:
To assign sequential names to source signal 2 through
source signal 4
1. In step 2 above, set knob 1 to "2," and set knob 2 to
2. Set the name of source signal 2 to "CAM2."
The name "CAM3" is assigned automatically to
source signal 3, and the name "CAM4" is assigned
automatically to source signal 4.
Setting the source name display color
1
In the Panel >Xpt Assign >Table Button Assign >Src
Name/LCD Color menu, turn the knobs to select the
setting target.
Knob Parameter Adjustment
1
2
2
In the <LCD Color> group, select the color (Orange/
Green/Yellow).

Copying Cross-Point Assign Tables

The contents of a cross-point assign table can be copied to
another cross-point assign table, and vice versa.
Notes
The contents of a sub table cannot be copied to the main
table.
1
In the Panel >Xpt Assign menu, press [Table Copy].
The Table Copy menu appears.
Setting values
The status area shows a list of copy sources and a list
of copy destinations.
1 to 326 (MVS-
8000X)
2
1 to 152 (MVS-
Using any of the following methods, select the number
7000X)
of the table to use as the copy source and the number
of the table you want to be the copy destination.
"3."
Source No Source signal
selection
Num
Number of
source signals to
be selected
Cross-Point Settings (Xpt Assign Menu)
Setting values
1 to 326 (MVS-
8000X)
1 to 152 (MVS-
7000X)