17–User Diagnostics in DOS
Performing Diagnostics
Performing Diagnostics
At the MS-DOS prompt, type uediag followed by the command options. The
uediag command options are shown in
diagnostic tests on adapter #1 except Group B tests:
C:\>uediag -c 1 -t b
NOTE
You must include uediag at the beginning of the command string each
time you type a command.
Command
Options
uediag
uediag -c
<device#>
uediag -cof
uediag -dev
<device#>
uediag -F
uediag -fbc
<bc_image>
uediag -fbc1
<bc1_image>
uediag -fbc2
<bc2_image>
uediag -fl2b
<l2b_image>
uediag -fib
<ib_image>
uediag -fibc
uediag -fibc2
Table 17-1. uediag Command Options
Performs all tests on all QLogic 8400/3400 Series adapters in
your system.
Specifies the adapter (device#) to test. Similar to -dev (for back-
ward compatibility).
Allows tests to continue after detecting a failure.
Specifies the adapter (device#) to test.
Forces an upgrade of the image without checking the version.
Specifies the bin file to update the bootcode.
Specifies the bin file to update bootcode 1.
Specifies the bin file to update bootcode 2.
Specifies the bin file for L2B firmware.
Specifies the bin file for iSCSI boot.
Programs iSCSI configuration block 0. Used only with -fib
<ib_image>.
Programs iSCSI configuration block 1. Used only with -fib
<ib_image>.
240
Table
17-1. For example, to run all
Description
83840-546-00 E