15–QLogic Teaming Services
Event Log Messages
Table 15-7. Base Driver Event Log Messages (Continued)
Message
Severity
Number
11
Informational
12
Informational
13
Error
14
Error
15
Error
16
Informational
17
Informational
18
Error
Message
Network controller
configured for 1Gb
full-duplex link.
Network controller
configured for 2.5Gb
full-duplex link.
Medium not sup-
ported.
Unable to register
the interrupt service
routine.
Unable to map IO
space.
Driver initialized suc-
cessfully.
NDIS is resetting the
miniport driver.
Unknown PHY
detected. Using a
default PHY initial-
ization routine.
226
Cause
The adapter has been
manually configured for
the selected line speed
and duplex settings.
The adapter has been
manually configured for
the selected line speed
and duplex settings.
The operating system
does not support the
IEEE 802.3 medium.
The device driver can-
not install the interrupt
handler.
The device driver can-
not allocate mem-
ory-mapped I/O to
access driver registers.
The driver has suc-
cessfully loaded.
The NDIS layer has
detected a problem
sending/receiving pack-
ets and is resetting the
driver to resolve the
problem.
The driver could not
read the PHY ID.
Corrective Action
No action is required.
No action is required.
Reboot the operating
system, run a virus
check, run a disk check
(chkdsk), and reinstall
the operating system.
Reboot the operating
system; remove other
device drivers that may
be sharing the same
IRQ.
Remove other adapt-
ers from the system,
reduce the amount of
physical memory
installed, and replace
the adapter.
No action is required.
Run QCC GUI diagnos-
tics; check that the net-
work cable is good.
Replace the adapter.
83840-546-00 E
Need help?
Do you have a question about the FastLinQ 3400 Series and is the answer not in the manual?