Siemens SINUMERIK 828D Function Manual page 589

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

NCK events
PROGMODESLASHON
PROGMODESLASHOFF
PROGMODEDRYRUNON
PROGMODEDRYRUNOFF
BLOCKREADINHIBIT_ON
STOPATEND_ALARM
STOP_ALARM
STOPATIPOBUFFER_ISEMPTY_ALARM
STOPATIPOBUF_EMPTY_ALARM_REORG
RETREAT_MOVE_THREAD
WAITMC
NEWCONF_PREP_STOP
BLOCKSEARCHRUN_NEWCONF
SET_USER_DATA
SYSTEM_SHUTDOWN
ESR
EXT_ZERO_POINT
STOPRUN
Reaction
The reaction to a stop event can be:
immediate
Stops immediately even in stop delay section. Is known as a "hard stop event".
delayed
Does not stop (even short-term) until after stop delay section. Is known as a "soft stop event".
Alarm 16954
Program is aborted because illegal program commands have been used in stop delay section.
Alarm 16955
Program is continued, an illegal action has taken place in the stop delay section.
Alarm 16957
The program section (stop delay section) enclosed by DELAYFSTON and DELAYFSTOF could not be activated.
As a result, every stop will take effect immediately and is not subject to a delay! This will always occur when
the deceleration begins before the stop delay area but ends within the stop delay area. Likewise, if the stop
delay area is entered with an override of 0, the stop delay area also cannot be activated. (example: a G4
before the stop delay section allows the user to reduce the override to 0. The next block in the stop delay
section then begins with override 0 and the described alarm situation occurs.)
Note
MD11411 $MN_ENABLE_ALARM_MASK (activation of warnings) Bit 7 activates this
alarm.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
K1: Mode group, channel, program operation, reset response
Response
Stop criteria
delayed
IS: DB21, ... DBB26 Activate/switch over skip block
delayed
IS: DB21, ... DBB26 deactivate skip block
delayed
IS: DB21, ... DBX0.6 Activate DryRun
delayed
IS: DB21, ... DBX0.6 Deactivate DryRun
delayed
IS: DB21, ... DBX6.1 Activate read-in disable
immediate
Alarm: Alarm configuration STOPATENDBYALARM
immediate
Alarm: Alarm configuration STOPBYALARM
immediate
Internal: Stop after alarm on empty IPO buffer
immediate
Internal: Stop after alarm on empty IPO buffer
Alarm 16954
NC prog.: Alarm 16954 at LFON (Stop & fast lift in G33
not possible
Alarm 16954
NC prog.: WAITMC
Alarm 16954
NC prog.: NEWCONF
Alarm 16954
NC prog.: NEWCONF
delayed
OPI: PI "_N_SETUDT"
immediate
System shutdown for SINUMERIK 840Di
delayed
Extended stop and retract
delayed
External work offset
Alarm 16955
OPI: PI "_N_FINDST" STOPRUN
9.9 Program operation mode
589

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d sl

Table of Contents