bintec W1002/W1002n/W2002/WIx040/WIx065
Pin
5
6
7
8
The Ethernet 10/100 BASE-T interface does not have an Auto-MDI-X function.
6.1.5.2 Serial Interface
Your device has a Serial interface for connection to a console. This supports Baud rates
from 1200 to 115200 Bps.
The interface is designed as a 9-pin SUB-D socket.
Fig. 17: 9-pin Sub-D connector
The pin assignment is as follows:
Pin assignment of the Sub-D port
Pin
bintec W1002/bintec W2002
function
1
CD
2
RxD
3
TxD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI

6.1.6 Frequencies and channels

Different certification regulations apply around the world. ETSI standards generally apply
(predominantly used in Europe). For operation in Europe, please read the notes in the
R&TTE Compliance Information.
Function Eth1 - PoE
Power
RD -/Power
Power
Power
6 Technical data
Function Eth 2
Not used
RD -
Not used
Not used
bintec W1002n function
Not used
RxD
TxD
Not used
GND
DSR
RTS
CTS
Not used