11 Wireless LAN
154
Field
CW Max.
Max. Receive Lifetime
Max. Transmit MSDU
Lifetime

11.1.2 Virtual Service Sets

If you operate your device in access point mode (Wireless LAN->WLANx-> Radio Set-
tings->
->Operation Mode = Access Point), you can set up and edit the desired wire-
less networks in the Wireless LAN->WLANx->Virtual Service Sets->
Setting network names
In contrast to a LAN set up over Ethernet, a wireless LAN does not have any cables for set-
ting up a permanent connection between the server and clients. Access violations or faults
may therefore occur with directly adjacent radio networks. To prevent this, every radio net-
Funkwerk Enterprise Communications GmbH
Description
Possible values are 1 to 65535.
The default value is 15.
Not for bintec W1002n
Here, you can define the minimum size of the contention win-
dow.
Possible values are 1 to 65535.
The default value is 1023.
Not for bintec W1002n
Enter the time from receipt of the first fragment of a data packet
as of which no further attempts are made. The data packet is
discarded.
Possible values are 1 to 4294967295.
The default value is 512 msec.
Not for bintec W1002n
Enter the time from sending of the first fragment of a data pack-
et as of which no further send attempts are made. The data
packet is discarded.
Possible values are 1 to 4294967295.
The default value is 512 msec.
bintec W1002/W1002n/W2002/WIx040/WIx065
->/New menu.