bintec W1002/W1002n/W2002/WIx040/WIx065
Field
Facility
Time Stamp
Protocol
Type of Messages

18.2 IP Accounting

In modern networks, information about the type and number of data packets sent and re-
ceived over the network connections is often collected for commercial reasons. This inform-
ation is extremely important for Internet Service Providers that bill their customers by data
volume.
Description
or identical priority to that indicated, i.e. all messages generated
are recorded at syslog level Debug.
Enter the syslog facility on the host.
This is only required if the Log Host is a Unix computer.
Possible values: local0 - 7
.
The default value is local0.
Select the format of the time stamp in the syslog.
Possible values:
• None (default value): No system time indicated.
• Time : System time without date.
• Date & Time : System time with date.
Select the protocol for the transfer of syslog messages. Note
that the syslog server must support the protocol.
Possible values:
• UDP (default value)
• TCP
Select the message type.
Possible values:
• System & Accounting (default value)
• System
• Accounting