Funkwerk Enterprise Communications GmbH
bintec W1002/W1002n/W2002/WIx040/WIx065
Local Services
Fig. 143:
->
The Local Services->Surveillance->Ping Generator->New menu consists of the follow-
ing fields:
Fields in the Ping GeneratorBasic Parameters menu
Field
Destination IP Address
Source IP Address
Interval
16.6 Funkwerk Discovery
Surveillance
Ping Generator
->
Description
Enter the IP address to which the ping is automatically sent.
Enter the source IP address of the outgoing ICMP echo request
packets.
Possible values:
• Automatic: The IP address is determined automatically.
• Specific (default value): Enter the IP address in the adja-
cent input field e.g. to test a particular extended route.
Enter the interval is seconds during which the ping is to be sent
to the target IP address specified in Target IP Address .
Possible values are 1 to 65536.
The default value is 10.
16 Local services
New
->
325