Chapter 5 Parameters|VFD-B Series
Group 4: Input Function Parameters
04 - 00
AVI Analog Input Bias
Settings
04 - 01
AVI Bias Polarity
Settings
04 - 02

AVI Input Gain

Settings
04 - 03
AVI Negative Bias, Reverse Motion Enable/Disable
Settings
04 - 11
ACI Analog Input Bias
Settings
04 - 12
ACI Bias Polarity
Settings
04 - 13
ACI Input Gain
Settings
04 - 14
ACI Negative Bias, Reverse Motion Enable/Disable
Settings
04 - 15

AUI Analog Input Bias

Settings
04 - 16
AUI Bias Polarity
Settings
04 - 17
AUI Input Gain
Settings
5-48
0.00 to 200.00%
00
Positive Bias
01
Negative Bias
1 to 200%
00
No AVI Negative Bias Command
01
Negative Bias: REV Motion Enabled
02
Negative Bias: REV Motion Disabled
0.00 to 200.00%
00
Positive Bias
01
Negative Bias
01 to 200%
00
No ACI Negative Bias Command
01
Negative Bias: REV Motion Enabled
02
Negative Bias: REV Motion Disabled
0.00 to 200.00%
00
Positive Bias
01
Negative Bias
01 to 200%
Unit: 0.01
Factory Setting: 0.00
Factory Setting: 00
Unit: 1
Factory Setting: 100
Factory Setting: 00
Unit: 0.01
Factory Setting: 0.00
Factory Setting: 00
Unit: 1
Factory Setting: 100
Factory Setting: 00
Unit: 0.01
Factory Setting: 0.00
Factory Setting: 00
Unit: 1
Factory Setting: 100