Multi-Function Input Terminal (Mi1-Mi6) - Delta VFD-B User Manual

High performance user-friendly powerful ac motor drives
Hide thumbs Also See for VFD-B:
Table of Contents

Advertisement

04 - 04
Multi-function Input Terminal (MI1)
04 - 05
Multi-function Input Terminal (MI2)
04 - 06
Multi-function Input Terminal (MI3)
04 - 07
Multi-function Input Terminal (MI4)
04 - 08
Multi-function Input Terminal (MI5)
04 - 09
Multi-function Input Terminal (MI6)
Settings
00
No Function
01
Multi-Step Speed Command 1
02
Multi-Step Speed Command 2
03
Multi-Step Speed Command 3
04
Multi-Step Speed Command 4
05
External Reset (N.O.)
06
Accel/Decel Inhibit
Accel/Decel Time Selection
07
Command 1
Accel/Decel Time Selection
08
Command 2
Revision July 2008, BE16, SW V4.08 & V5.00
Function
Description
Any unused terminals should be programmed to 0 to
insure they have no effect on operation.
These four inputs select the multi-speed defined by
Pr.05-00 to Pr.05-14 as shown in the diagram at the
end of this table.
NOTE: Pr.05-00 to Pr.05-14 can also be used to
control output speed by programming the AC motor
drive's internal PLC function. There are 17 step
speed frequencies (including Master Frequency and
Jog Frequency) to select for application.
The External Reset has the same function as the
Reset key on the Digital keypad. After faults such as
O.H., O.C. and O.V. are cleared this input can be
used to reset the drive.
When the command is active, acceleration and
deceleration is stopped and the AC motor drive
maintains a constant speed.
Used to select the one of four Accel/Decel Times
(Pr.01-09 to Pr.01-12, Pr.01-18 to Pr.01-21). See
explanation at the end of this table.
Chapter 5 Parameters|VFD-B Series
Factory Setting: 01
Factory Setting: 02
Factory Setting: 03
Factory Setting: 04
Factory Setting: 05
Factory Setting: 06
5-53