Parameter
Explanation
Digital Terminal
04-10
Input Debouncing
Time
ACI Analog Input
04-11
Bias
04-12
ACI Bias Polarity
04-13 ACI Input Gain
ACI Negative Bias,
04-14
Reverse Motion
Enable/Disable
AUI Analog Input
04-15
Bias
04-16
AUI Bias Polarity
04-17 AUI Input Gain
AUI Negative Bias
04-18
Reverse Motion
Enable/Disable
AVI Analog Input
04-19
Delay
ACI Analog Input
04-20
Delay
AUI Analog Input
04-21
Delay
Analog Input
04-22
Frequency
Resolution
Gear Ratio for
04-23
Simple Index
Function
Index Angle for
04-24
Simple Index
Function
Deceleration Time
04-25
for Simple Index
Function
Revision July 2008, BE16, SW V4.08 & V5.00
Settings
31: Source of second frequency command
enabled
32: Source of second operation command
enabled
33: One shot PLC
34: Proximity sensor input for simple Index
function
35: Output shutoff stop (NO)
36: Output shutoff stop (NC)
1 to 20 (*2ms)
0.00~200.00 %
00: Positive bias
01: Negative bias
01 to 200 %
00: No ACI negative bias command
01: Negative bias: REV motion enabled
02: Negative bias: REV motion disabled
0.00~200.00 %
00: Positive bias
01: Negative bias
01 to 200 %
00: No AUI negative bias command
01: Negative bias: REV motion enabled
02: Negative bias: REV motion disabled
0.00 to 10.00 sec
0.00 to 10.00 sec
0.00 to 10.00 sec
00: 0.01Hz
01: 0.1Hz
4 ~ 1000
o
0.0 ~360.0
0.00 ~100.00 sec
Chapter 5 Parameters|VFD-B Series
Factory
Setting
01
0.00
00
100
00
0.00
00
100
00
0.05
0.05
0.05
01
200
180.0
0.00
Customer
5-9