The base is Pr.01-00. When in PID feedback control, if | Source of PID reference target -
feedback | > Pr.10-16 and exceeds Pr.10-08 detection time, the AC drive will operate
according to Pr.10-09.
10 - 10

PG Pulse Range

Settings
A Pulse Generator (PG) or encoder is used as a sensor that provides a feedback signal of the
motor speed. This parameter defines the number of pulses for each cycle of the PG control.
For PG or encoder feedback an option PG-card is needed.
10 - 11

PG Input

Settings
The relationship between the motor rotation and PG input is illustrated below:
FWD
REV
PULSE
GENERATOR
10 - 12

ASR (Auto Speed Regulation) control (with PG only) (P)

Settings
This parameter specifies Proportional control and associated gain (P), and is used for speed
control with PG (encoder) feedback.
NOTE
The parameter can be set during operation for easy tuning.
Revision July 2008, BE16, SW V4.08 & V5.00
1 ~ 40000 (Max=20000 for 2-pole motor)
00
Disable PG
01
Single phase
02
Forward / Counterclockwise rotation
03
Reverse / Clockwise rotation
PG
0.0 to 10.0
Chapter 5 Parameters|VFD-B Series
A phase leads B phase
A phase
CCW
B phase
10-11=02
B phase leads A phase
A phase
CW
B phase
10-11=03
A phase
CW
B phase
Unit: 1
Factory Setting: 600
Factory Setting: 00
Unit: 0.1
Factory Setting: 1.0
5-99