kW
HP
18.5
25
22
30
30
40
37
50
45
60
55
75
75
100
B.6.3 Applications for AC Reactor
Connected in input circuit
When more than one AC motor drive is
connected to the same power, one of them is
ON during operation.
Correct wiring
Silicon rectifier and AC motor drive is
connected to the same power.
Revision July 2008, BE16, SW V4.08 & V5.00
Fundamental
continuous
Amps
25
35
45
55
80
80
100
Application 1
reactor
M1
M2
Mn
Application 2
Appendix B Accessories|VFD-B Series
Max.
3% impedance
Amps
37.5
1.2
52.5
0.8
67.5
0.7
82.5
0.5
120
0.4
120
0.4
150
0.3
When applying to one of the AC motor drive,
the charge current of capacity may cause
voltage ripple. The AC motor drive may
damage when over current occurs during
operation.
AC motor drive
AC motor drive
AC motor drive
Surges will be generated at the instant of
silicon rectifier switching on/off. These surges
may damage the mains circuit.
Inductance (mH)
5% impedance
1.8
1.2
1.2
0.85
0.7
0.7
0.45
Question