User Defined Coefficient K - Delta VFD-B User Manual

High performance user-friendly powerful ac motor drives
Hide thumbs Also See for VFD-B:
Table of Contents

Advertisement

00 - 04
Content of Multi-Function Display
07
08
09
10
11
12
13
14
This parameter sets the display when Pr. 00-03 is set to 03.
Pr.00-04=09. The display value is (((rpm/60)*PPR)/1000ms)*10ms
with rpm=motor speed in revs/min and PPR=encoder pulse per revolution
When the display shows the multi-function display (Pr.00-03=03), the user also can view other
information by pressing the "LEFT" key
00 - 05

User Defined Coefficient K

Settings
The coefficient K determines the multiplying factor for the user-defined unit.
The display value is calculated as follows:
U (User-defined unit) = Frequency Command * K (Pr.00-05)
H (actual output) = Actual output frequency * K (Pr.00-05)
Example:
A conveyor belt runs at 13.6m/s at motor speed 60Hz.
K = 13.6/60 = 0.23 (0.226667 rounded to 2 decimals), therefore Pr.00-05=0.23
With Frequency command 35Hz, display shows LED U and 35*0.23=8.05m/s.
(To increase accuracy, use K=2.27 or K=22.67 and disregard decimal point.)
Revision July 2008, BE16, SW V4.08 & V5.00
Display the actual motor speed in rpm (enabled in
vector control mode or PG (Encoder) feedback control)
(LED H and LED U).
Display the estimated value of torque in Nm as it relates
to current.
Display PG encoder feedback pulses/10ms.
Display value= (rpm*PPR)/6000 (see note)
Display analog feedback signal value in %.
Display the signal of AVI analog input terminal in %.
Range 0~10V corresponds to 0~100%. (LED U)
Display the signal of ACI analog input terminal in %.
Range 4~20mA corresponds to 0~100%. (LED U)
Display the signal of AUI analog input terminal in %.
Range -10V~10V corresponds to 0~100%. (LED U)
Display the temperature of heat sink in °C.
0.01 to d 160.00
Chapter 5 Parameters|VFD-B Series
on the VFD-PU01 keypad.
Unit: 0.01
Factory Setting: 1.00
5-25

Hide quick links:

Advertisement

Table of Contents
loading