Delta VFD-B User Manual page 215

High performance user-friendly powerful ac motor drives
Hide thumbs Also See for VFD-B:
Table of Contents

Advertisement

Appendix B Accessories|VFD-B Series
a)
Please use a shield cable to prevent interference. Do not run control wire parallel to
any high voltage AC power line (220V and up).
b)
Connect shielded wire to
c)
Recommended wire size 0.21 to 0.81mm
d)
Wire length:
The Output Types of
Output Voltage
Open Collector
Complementary
3. Control Terminals Block Designations.
B-28
Maximum Wire
the Encoder
Line Driver
Connect to the
Series Control Board
PG-03
G
Select the input
B
power and the
output type of the
A
Encoder
E only.
2
(AWG24 to AWG18).
Length
50m
50m
1.25mm
300m
70m
VFD
FSW2
OC
TP
Revision July 2008, BE16, SW V4.08 & V5.00
Wire Gauge
2
(AWG16) or above
B/O
A/O
0V
12V
0V
B
B
A
A