Solution 6000
Installation Manual
System > Siren >

Siren Swinger

(*** System Wide Parameter ***)
This menu allows you to program how many times a zone
programmed for Lockout Siren can sound the siren during
each arming cycle.
At default, zones programmed for Lockout Siren will be
able to trigger the siren 3 times before being locked out.
The count will be reset when the system or area is next
disarmed.
1) Press [MENU] + [7] + [4] + [3]. The keypad will
display the current Swinger Siren count.
Siren Swinger
3
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the new swinger
siren count. Valid entries are 0 to 15 where 0 =
unlimited.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
11-10
System Programming
MENU 7-4-3
3
0
T I M E ZO N E S
The control panel has 2 fixed timezones (Tz0 - Disabled and
Tz1 - 24 Hr TimeZone) and 15 programmable timezones.
A timezone is created by setting up a valid time period
that becomes TRUE whenever the time is equal to or after
the start time and before the end time for the selected
day.
There are 2 default timezones created within the system
that cannot be changed. These are Tz0 = Disabled - which
is FALSE 24/7 and Tz1 = 24 Hour which is TRUE 24/7 (TZ1
being the opposite of Tz0). Tz2 to 16 are configurable to
reflect any operation time and day as required to operate,
restrict, or control when something happens. Please
refer to the following table that illustrates the effect of
assigning timezones.
Assigned To Tz0 (Disabled)
Door
Door Lock
Door Group
Egress
Auto Arming
Output
Assigned To Tz1 (24 Hr)
Door
Door Lock
Door Group
Egress
Auto Arming
Output
Table 35: Fixed Timezones (Tz0 & Tz1)
In previous versions, events programmed to follow
i
timezones may fail to operate if the automatic test
Note
report option has been enabled. In version 2.14, this
has been corrected.
Resulting Effect
No access
Will never unlock
No access
Will never trigger
Will never arm (Same as Tz1)
Will never trigger
Resulting Effect
Full 24 hr access
Unlocked 24 hrs
Full 24 hr access
Operates 24 hrs
Will never arm (Same as Tz0)
Always triggered