Table of Contents

Advertisement

Quick Links

Solution 6000-IP
Security Systems
User Guide
EN
Security System

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Solution 6000-IP

  • Page 1 Solution 6000-IP Security Systems User Guide Security System...
  • Page 2: Copyright Notice

    Notice to O wn e r Thankyou for selecting the Solution 6000-IP Security Control Panel for your security needs. Your system includes many advanced features and functions which will be programmed and configured by your security consultant during installation. Depending on the configuration, and your access level, you may have the ability to program certain features within the system to suit changes in your security needs.
  • Page 3: Table Of Contents

    Chime Mode .................19 Area Name ..................19 Part Mode 1 Name ..............19 Part Mode 2 Name ..............19 Auto Arming .................20 Exit Time ..................20 Entry Time 1 ..................20 Entry Time 2 ..................21 Part Entry Time ................21 Inputs ..................22 Bosch Security Systems 10/22 BLCC615U...
  • Page 4 Solution 6000-IP User Guide This page left intentionally blank Bosch Security Systems 10/22 BLCC615U...
  • Page 5: Program Menu Tree

    7-5-3 TimeZone Options Holidays 7-6-0 Holiday Name 7-6-1 Start Stop Dates System Options 7-7-3 Keypad Hi/Lo Temp 7-7-7 Site Name System Testing 7-9-0 Walk Test All Zones 7-9-1 Battery Test Table 1: Control Panel Menu Tree Bosch Security Systems 10/22 BLCC615U...
  • Page 6: Introduction

    Fe at ures faulted zones. Listed below are the main features of the Solution 6000-IP Zones Types control panel. There are two basic types of zones, Non 24-hour and 24- ƒ...
  • Page 7: Reporting Alarms

    The [PART] key allows you to turn an area Part On. This key can also be used to bypass a zone or multiple zones when you press and hold for two seconds. Figure 1: Keypad Emergency Alarm Triggers Bosch Security Systems 10/22 BLCC615U...
  • Page 8: Status Icons / Led's

    User Programming Mode is Active Exit the last 10 seconds fast short beeps will be Delay heard. If you don’t exit before the delay time Tone expires and an exit delay door is faulted, an alarm occurs. Bosch Security Systems 10/22 BLCC615U...
  • Page 9: Basic System Operation

    PIN followed by the [OFF] key. off. The keypad will no longer display the ‘Lock’ or 3. To turn the system (or area) off, enter your PIN, then ‘Part’ icons. press [OFF]. Bosch Security Systems 10/22 BLCC615U...
  • Page 10: Silencing Alarms

    Pressing the same numeric key repeatedly will step you through the available characters assigned to the key. The text key layout is the same as most phones. Refer to the table below for detailed character information. Bosch Security Systems 10/22 BLCC615U...
  • Page 11: Duress Or Silent Alarms

    At factory default, each PIN is fixed to 4 digits in length. 2. Verify the user name to be erased and press [OK]. The default PIN for User 1 (Master user) is 2580. To abort press [MENU]. Enter programming mode (PIN + MENU) then, Bosch Security Systems 10/22 BLCC615U...
  • Page 12: Add Pin

    If an error tone sounds, try a different new PIN. 2. Use the [] and [] keys to select the user that you 4. Press [OK] to save and exit, or press [MENU] to exit Bosch Security Systems 10/22 BLCC615U...
  • Page 13: Delete Token

    [OK]. 1. Enter [MENU] + [1] + [2] + [2]. The system will prompt you to present the token to The keypad will prompt you to enter the RF keyfob the keypad. Bosch Security Systems 10/22 BLCC615U...
  • Page 14: Delete Keyfob

    [OK] to select. Alternatively, you can enter the Follow the procedure below to configure the required user number you want to program, then press [OK]. options. Bosch Security Systems 10/22 BLCC615U...
  • Page 15: Timezones

    01 Jan 2100 3. Press [OK] to save and exit or press [MENU] to exit Press OK to SAVE  without saving. 3. Press [OK] to save and exit, or press [MENU] to exit without saving. Bosch Security Systems 10/22 BLCC615U...
  • Page 16: Fingerprints

    A list of users will display on the keypad. 2. Use the [] and [] keys to select the user who’s fingerprint you want to delete, then press [OK] to select. Figure 3: CM729B Fingerprint Reader Bosch Security Systems 10/22 BLCC615U...
  • Page 17: Fingerprint Status

    Alternatively, you can enter the area number you 1. Enter [MENU] + [2] + [0] + [0]. want to turn on or off, then press [OK]. A list of available areas will display on the keypad. Bosch Security Systems 10/22 BLCC615U...
  • Page 18: Turn All Areas On

    Reception Area A1 1. Enter [MENU] + [2] + [0] + [4]. Chime is ON. To turn OFF, Press OFF. A list of different areas will display on the keypad. To Go Back Press OK Bosch Security Systems 10/22 BLCC615U...
  • Page 19: Chime Mode

    Alternatively, you can enter the area number that you want to program the name, then press 1. Enter [MENU] + [2] + [1] + [7]. [OK]. A list of different areas will display on the keypad. Bosch Security Systems 10/22 BLCC615U...
  • Page 20: Auto Arming

    The entry time is the amount of time you have to turn your number that you want to program, then press [OK]. alarm system off once the entry zone have been triggered The keypad will display the following: or opened. Bosch Security Systems 10/22 BLCC615U...
  • Page 21: Entry Time 2

     [OK] to select. Alternatively, you can enter the area number that you want to program, then press [OK]. 2. Use the [] and [] keys to select the area that you Bosch Security Systems 10/22 BLCC615U...
  • Page 22: Inputs

    A list of zones that can be bypassed will display on the keypad. A ‘√’ displayed on the right side of Enter programming mode (PIN + MENU) then, the zone name indicates that the zone is already bypassed. Bosch Security Systems 10/22 BLCC615U...
  • Page 23: Set Chime Zones

    If the zone is not programmed for Part 2, the keypad Zn3 Zone 3 Name will prompt: Press OK or MENU  3. Use the [] and [] keys to select the zone that you want to set for chime, then press [OK]. Alternatively, Bosch Security Systems 10/22 BLCC615U...
  • Page 24: Smoke Sensor Reset

    [OK] to select. 4. Press [OK] to save and exit, or press [MENU] to exit Alternatively, you can enter the zone number, then without saving. press [OK]. The keypad will display the following: Bosch Security Systems 10/22 BLCC615U...
  • Page 25: Walk Test A Single Zone

    [OK] to select. Alternatively, you can enter the To Go Back Press OK output number and then press [OK]. The keypad will display the following when the To turn the output on, press [ON]. output is off and OK: Bosch Security Systems 10/22 BLCC615U...
  • Page 26: Output Array

    4. Use the [] and [] keys to move up and down the output array and when finished press [OK] or [MENU] to exit. 1. Enter [MENU] + [4] + [0] + [4]. The keypad will Bosch Security Systems 10/22 BLCC615U...
  • Page 27: Door Control

    [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key. 4. Press [OK] to save and exit, or press [MENU] to exit without saving. Bosch Security Systems 10/22 BLCC615U...
  • Page 28: External Siren Test

    The test will want to test the internal sirens in, then press [OK]. last for 5 seconds. Alternatively, you can enter the area number, then press [OK]. Enter programming mode (PIN + MENU) then, Bosch Security Systems 10/22 BLCC615U...
  • Page 29: Communication / Reporting

    This menu allows the master user to start a direct link session. You should discuss this option with your installer. Enter programming mode (PIN + MENU) then, 1. Enter [MENU] + [5] + [0] + [5]. Bosch Security Systems 10/22 BLCC615U...
  • Page 30: Devices And Optional Modules

    3. Press [OK] to save and exit, or press [MENU] to exit 1. Enter [MENU] + [6] + [1] + [0]. without saving. A list of available devices will display on the keypad. 2. Use the [] and [] keys to select the device name Bosch Security Systems 10/22 BLCC615U...
  • Page 31: System Events

    A brief description of the options available are listed below. Line 1 Displays: For more information refer to the Wi-Fi Enabled Keypad IRG. The panel number that you are getting information from. The Solution 6000-IP is only configured to work with one panel. SSID Scan Line 2 Displays: This option will request the system to create a list of all The panel name and firmware version number.
  • Page 32: System Trouble

     2. If viewing system trouble conditions, the keypad will display similar to the following: Panel 1 Solution 6000-IP Ver 3.00 Date And Time Press OK or MENU The third line of the keypad display scrolls between all current system trouble events.
  • Page 33 The system has detected an error with its internal memory. Memory Checksum You should contact your security company. Battery Trouble The system has detected that the Real Time Clock Module backup battery voltage is low or missing Table 8: Control Panel Trouble Messages Bosch Security Systems 10/22 BLCC615U...
  • Page 34: History Log

    Kp1 Keypad 1 Name Panel 1 - = TimeZones 06 to 08 and TimeZones 13 to 16 are Dest 1 at 01-Apr 03:41:57 disabled or not used. 3. Press [OK] or press [MENU] to exit. Bosch Security Systems 10/22 BLCC615U...
  • Page 35: Set Date And Time

    Tz3 TimeZone 3 Name Tz4 TimeZone 4 Name the week. Press OK or MENU The following options allow you to vary or change the  Bosch Security Systems 10/22 BLCC615U...
  • Page 36: Day

    3. Use the [] and [] keys to select the period in the Press OK to SAVE  timezone that you want to change, then press [OK] to select. 3. To program the holiday name, use the [] and [] The keypad will display the following: Bosch Security Systems 10/22 BLCC615U...
  • Page 37: Start / Stop Day

    Alternatively, you can enter the area number, then  press [OK]. The keypad will scroll all zones that you can test. 2. Use the [] and [] keys to program the ‘High’ and ‘Low’ temperatures. To toggle between the ‘High’ Bosch Security Systems 10/22 BLCC615U...
  • Page 38: Battery Test

    To Go Back Press OK If the battery has passed the test, the keypad will display: Battery Test Passed Press OK To Continue To Go Back Press OK If the battery has failed the test, the keypad will display: Bosch Security Systems 10/22 BLCC615U...
  • Page 39 Solution 6000-IP User Guide This page left intentionally blank Bosch Security Systems 10/22 BLCC615U...
  • Page 40: Installation Details

    Solution 6000-IP User Guide I nst al lat i on D et a il s INSTALLED BY: DATE PHONE: FAX: EMAIL: SERVICE PHONE: FAX: EMAIL: MONITORED BY: PHONE: FAX: EMAIL: WARRANTY EXPIRES: NOTES: Bosch Security Systems 10/22 BLCC615U...
  • Page 41 Turning An Area Part On ............9 Emergency Alarms Add PIN ................... 12 Keypad Alarm Triggers ............7 Change Own PIN ..............11 Delete a PIN ................12 Features ..................6 Fingerprints ................16 RF Keyfob Add 16 Add 13 Bosch Security Systems 10/22 BLCC615U...
  • Page 42 All Zones ................24, 37 Web Email ................. 29 WiFi Settings Password ................31 Security ................... 31 SSID 31 SSID Scan ................31 Zone 24-Hour Zones ................6 Array ..................22 Bypass Command ..............22 Bypass Zones ................. 22 Bosch Security Systems 10/22 BLCC615U...
  • Page 43 Solution 6000-IP User Guide This page left intentionally blank Bosch Security Systems 10/22 BLCC615U...
  • Page 44 Bosch Security Systems Level 2, 21 Solent Circuit Baulkham Hills, NSW 2153 Australia Phone: 1300 026 724 www.boschsecurity.com.au © 2022 Bosch Security Systems BLCC615U Issue FTR1.1...

Table of Contents