handover pulses to other 24 hour non fire zones. A 24-
hour fire zone can only handover pulses to another 24-
hour fire zone.

Senior Watch

This option requires at least one burglary zone in the
corresponding area to be faulted and restored during
the senior watch time. If no burglary zone has register
during the senior watch time, the keypad will sound an
alarm.
To warn the user that senior watch time is about to
expire, the keypad will sound the auto arm pre-alert time
(if programmed) prior to sounding the alarm. See MENU
2-8-6 — Senior Watch Time.
This feature is not applicable when the corresponding
area is turned All On.
An output (Output Event Type 51) can be programmed to
operate as follow senior watch if required.
Reset Smoke On Arming
This option when set, will trigger any output that is
programmed as event type 49 - Smoke Sensor GND to
operate on the next arming cycle, therefore resetting the
connected smoke sensors each time the area is armed.
If this option is not set then a manual reset will need to
be performed via MENU 3-0-5.
Areas > Area Properties >

Output Options

1

SPK Beeps Keyfob

2

SPK Beeps Key/Sw

3

SPK Strobe In Part On

4

Alarm On PIN Retry

5

Alarm Exit Error

6

Alarm Key/Sw Tamper

7
Reserved
8
Reserved
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [3] and select the area
from the list then press [OK].
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
 SPK Beeps Keyfob
 SPK Beeps Key/SW
 SPK Strobe In Part ON

Press
OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Bosch Security Systems 07/14 BLCC610I
SPK Beeps Keyfob
This option allows audible beeps via the speaker output
to verify to the user that they have successfully turned
the area On or Off using the RF keyfob. The speaker
output will sound one beep for Off (disarm), two beeps
for All On and three beeps for Part On.
SPK Beeps Key/Sw
This option allows audible beeps via the speaker output
to verify to the user that they have successfully turned
the area On or Off using a keyswitch input. The speaker
output will sound one beep for Off (disarm), two beeps
for All On and three beeps for Part On.
SPK Strobe In Part On
This option allows the strobe and audible alarms to
operate when the area is turned Part On or Part 2 On.
Alarm On PIN Retry
When the PIN retry count as programmed in MENU 1-5-1
is reached, an audible alarm will occur.
Alarm Exit Error
This option allows you to sound an alarm when an exit
error occurs.
An exit error occurs when an entry/exit delay zone
becomes unsealed during the exit delay time and
remains unsealed at the end of exit delay time. If this
happens, the entry delay will start. If the area is not
turned off (disarmed) before the entry delay time expires,
MENU 2-1-3
an alarm will occur.
Y
Alarm Key/Sw Tamper
Y
This option allows you to sound an alarm when a tamper
Y
condition occurs on a zone programmed as a keyswitch
Y
input. Refer to MENU 3-1-1 — Zone Type for information
N
on programming zones to be a keyswitch input.
Y
Areas > Area Properties >
N

Reporting Options

N
1
2
3
4
5
6
7
8
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [4] and select the area
2) Use the up and down arrow keys to highlight the
Solution 6000
Installation Manual
Report PIN Retry
Report Exit Error
Smart Lockout
Reserved
Cancel Report
Reserved
Op/Cl In Part On
Op/Cl After Alarm
from the list then press [OK].
option then press the [ON] key to enable or the
[OFF] key to disable.
Area Programming
MENU 2-1-4
Y
Y
N
N
Y
N
N
N
6-5