Keyswitch Options; Input Options; Tamper On Short; Response Time 500Msec - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

1) Press [MENU] + [3] + [4] + [1]. The keypad will
display the current keyswitch options (Default = 0
Disabled).

Keyswitch Options

00 - Latching All On/Off
Press  0-9 OK to SAVE
2) Use the up and down arrows to select the required
keyswitch option then press [OK] to save and exit
or press [MENU] to exit without saving.
Inputs > Global Input Options >

Input Options

1

Tamper On Short

2
Reserved
3

Response Time 500msec

4
Reserved
5

Keyswitch Open Close

6

Alarm On Tamper

7
Reserved
8
Reserved
(*** System Wide Parameter ***)
This menu programs the various global input options
which will effect all zones on the system.
1) Press [MENU] + [3] + [4] + [2]. The keypad will
display the current input options.
Tamper On Short
Reserved
Response Time 500msec
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Tamper On Short
Setting this option will cause any Zone which become
shorted to report a tamper alarm condition for the zone.
Response Time 500msec
Setting this option will increase the response time for all
zones to 500ms.
Bosch Security Systems 07/14 BLCC610I
Keyswitch Open Close
This feature allows you to select whether or not a zone
programmed as a Keyswitch Zone, will send opening and
closing reports. The default is set to Off.
Alarm On Tamper
This option allows tamper circuits on RF sensors and
hardwire zones to sound an alarm when faulted when
their corresponding area is turned off (disarmed).
Inputs > PGM Input >

Input Type

MENU 3-4-2
00 - Disabled
01 - Latching On/Off
N
02 - Pulse On/Off
N
03 - Simple RF On/Off
N
This menu option is used to configure the systems
N
programmable input terminal. Various devices can be
Y
connected including keyswitches of radio controlled relays
N
etc. When RF zones are required you need to connect the
N
RF receiver to this input
N
Connect keyswitch between Input terminal and GND.
See Wiring Diagrams in Section 3 for various connection
diagrams.
1) Press [MENU] + [3] + [5] + [0]. The keypad will
2) Use the up and down arrows to select the required
i
Note
Solution 6000
Installation Manual
display the current input type (Default = 0
Disabled).
Input Type
00 - Disabled
Press  0-9 OK to SAVE
Input Device Type then press [OK] to save and exit
or press [MENU] to exit without saving.
The Latching and Momentary On/Off modes
are active low, and when triggered, they will
automatically force arm the area.
Input Programming
MENU 3-5-0
0
04 - Bosch Serial Rcvr
05 - Crow Serial Rcvr (TBA)
0
7-13