Installation Manual
Open 1 Shot Low
Output is normally open circuit and switches to GND
when the event occurs. The output will only reset
when the time specified in the Time Parameter expires.
The output will run for the full duration and cannot be
manually reset.

1 Shot Low+Retrigger

Output is normally open circuit and switches to GND
when the event occurs. The output will retrigger each
time the event occurs. The output will reset when the
one shot time has expired.
This polarity is ideally suited for security lighting control.
A sensor can be used to trigger an output event and then
each time the sensor triggers, the output will operate.
The light will turn off when the one shot timer expires.
1 Shot Low + Reset
Output is normally open circuit and will switch to GND
when the event occurs. The output will reset when the
one shot timer expires or when the event has restored.
This means the operation of the output can be shortened
based on the event and or the programmed time
parameter.
Low To Open
Output is normally GND and will switch to open circuit
when the event occurs. The output will reset when the
output event restores. Time parameters do not apply to
this polarity type.
Low To Open + Pre
Output is normally GND and will switch to open circuit
when the event occurs provided the time parameter has
expired. The output will reset when the output event
restores. Time parameters will only set the Pre Delay
when this polarity is selected.
In version 2.04 this output has been corrected. In
i
previous versions, this output polarity would fail to
Note
operate when the time parameter is set as zero (ie. No
pre-delay time).
Low Latching Open
Output is normally GND and will switch to open circuit
when the event occurs. The output can only be reset
maually usning the output Command Menu.
Low Pulsing Open
Output is normally LOW and will pulse OPEN when the
event occurs. The output will reset when the output
event restores. Use the Time Parameter to set the pulse
duration.
Low 1 Shot Open
Output is normally LOW and will switch to open circuit
when the event occurs. The output will only reset
when the time specified in the Time Parameter expires.
8-10
Output Programming
The output will run for the full duration and cannot be
manually reset.
1 Shot Open+Retrigger
Output is normally LOW and will switch to open circuit
when the event occurs. The output will retrigger each
time the event occurs. The output will reset when the
one shot time has expired.
1 Shot Open + Reset
Output is normally LOW and will switch to open circuit
when the event occurs. The output will reset when the
one shot timer expires or the event has restored. This
means the operation of the output can be shortened
based on the event and or the programmed time
parameter.
Speaker Output
This polarity can only be used for Output 1 and Output 2
when a horn speaker has been connected.
Toggle
This polarity allows the output to turn on when the event
occurs. The output will toggle off when the event occurs
again. This polarity does not follow any time parameters.
T I M E D O U T P U T S
Outputs > Properties >

Time Parameter

0
0
0
0
0
Hour
Minute
The time base parameter is only applicable for output
types that are programmed as one shot or pulsing.
Program 0 to 255 for each of the units (Hour, Minute,
Seconds and 10th of a Second) for the time parameter. If
required, add the units together to give the total one shot
time or pulsing on/off time.
1) Press [MENU] + [4] + [1] + [4] and select the output
you want to program from the list then press [OK].
Alternatively, you can directly enter the output
number then press [OK].
2) Using the numeric keys, enter the length of time for
each parameter. If required, use the [←] and [→]
keys to move the cursor left and right between
each time parameter.
Output Timing Op1
Hrs
Mins
000
005
Press  OK to SAVE
3) Press [OK] to save and exit or press [MENU] to exit
without saving.

One Shot Mode

The time base is the length of time that the output will
MENU 4-1-4
0
0
0
0
0
Seconds
10
Sec
Tenth
000
000
Bosch Security Systems 07/14 BLCC610I
0
0
Sec
th

Hide quick links: