Test Route; System Route; Emergency Route; Swinger Dialler - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Comms > Reporting >

Test Route

00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
(*** System Wide Parameter ***)
This menu programs which destination will be used to
send both manual and automatic test reports.
1) Press [MENU] + [5] + [4] + [2]. The keypad will
display the current Test Route.
Test Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test
Route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Reporting >

System Route

00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
(*** System Wide Parameter ***)
This menu sets the report destination that will be used to
send all system event reports.
1) Press [MENU] + [5] + [4] + [3]. The keypad will
display the current Status Report route.
System Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
2) Use the up and down arrow keys to select the Test
Route required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Comms > Reporting >

Emergency Route

00 - Log Events Only
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Bosch Security Systems 07/14 BLCC610I
(*** System Wide Parameter ***)
MENU 5-4-2
This menu programs the destination that all Keypad
emergency alarms are reported.
0
1
1) Press [MENU] + [5] + [4] + [4]. The keypad will
2) Use the up and down arrow keys to select the
Comms > Reporting >

Swinger Dialler

(*** System Wide Parameter ***)
Swinger Dialler can be used to prevent a faulty or run-
a-way PIR from continually re-triggering the zone and
reporting to the base station.
The Swinger Dialler count sets the maximum number of
times an individual zone can trigger an alarm during the
MENU 5-4-3
current arming cycle before it is locked out.
0
1
If this option is not programmed, the panel will continue
to report the alarm signal until the system or area is
disarmed.
Only zones that have been programmed for Lockout
Dialler in MENU 3-1-7 — Report Options will follow the
Swinger Dialler count.
1) Press [MENU] + [5] + [4] + [5]. The keypad will
2) Using the numeric keys, enter the new Swinger
MENU 5-4-4
0
1
Solution 6000
Installation Manual
display the current Emergency Route.
Emergency Route
01 - Dest 1 + Log
Press  0-9 OK to SAVE
Keypad Emergency route required then Press [OK]
to save and exit or press [MENU] to exit without
saving.
display the current Swinger Dialler count.
Swinger Dialler
6
Press 0-9 OK to SAVE
Dialler count then press [OK] to save and exit or
press [MENU] to exit without saving. Valid entries
are 0 - 15 / 0 = disabled.
Comms Programming
MENU 5-4-5
0
6
9-15