Exit Time Restart; Reset Alarm Memory; Duress Allowed; Fault Ack Required - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Solution 6000
Installation Manual

Exit Time Restart

The exit delay timer will restart (once per arming cycle)
when the same entry/exit delay zone is faulted a second
time during exit delay (eg. If an entry/exit delay zone is
unsealled, restored and unsealled a second time during
exit delay = exit time restart).

Reset Alarm Memory

Clears all alarm memories displayed on the keypad when
a user has turned the corresponding area off. If this
option is not set, alarm memory will continue to display
until the user has turned the corresponding area on
again.

Duress Allowed

If a user is being forced to turn off the security system
under duress, they can disarm the system and initiate a
silent duress alarm.
To trigger the duress alarm enter your PIN then repeat
the last two digits of your PIN before pressing [ON], [OFF],
or [OK] key.
Example:
If your PIN is 2580, to send a duress report when the area
is off,
Enter, [2] [5] [8] [0] + [8] [0] + [OK] or [ON].
If your PIN is 2580, to send a duress report when the area
is on,
Enter, [2] [5] [8] [0] + [8] [0] + [OFF].

Fault ACK Required

If this option has been programmed, the control panel
will force a user to acknowledge each trouble condition
even though the trouble condition has already cleared.
If this option is not programmed, any trouble condition
that occurs will not have to be acknowledged if it has
already been rectified or cleared.

One Key Arming

This option allows users to simply press the [ON] key to
turn the area All On. All zones being armed must be
sealed. If open and close reports are programmed, the
user ID number will report as 000.

One Key Part On

This option allows users to simply press the [Part On]
key to turn the area Part On. All zones being armed
must be sealed. If open and close reports for Part On is
programmed, the user ID number will report as 000.

Link To Common Area

This option causes the selected area or areas to control
the common area. If this option is not selected for an
area then it will be able to operate independant of the
common area. See MENU 7-7-1 — Area Options to
enable the common area.
6-4
Area Programming

One Key Part Off

This option allows users to disarm from Part On or Part 2
On, simply by pressing the [OFF] key. This function will
only work if there are no alarms in effect, and the entry
timer is not running.
Areas > Area Properties >

Input Options

1

Non Sequential

2

Pulse Count H/Over

3
Senior Watch
4
Reset Smoke On Arming
5
Reserved
6
Reserved
7
Reserved
8
Reserved
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [2] and select the area
from the list then press [OK].
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
 Non Sequential
 Pulse Count H/Over
Senior Watch

Press
OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Non Sequential
With non-sequential entry path, you can trigger
handover zones in any order provided that an entry delay
zone was triggered first.
If this option is not programmed, handover zones must
be triggered in numerical sequence provided that an
entry delay zone was triggered first.
If a handover zone is triggered before an entry delay
zone is triggered an instant alarm will occur.
Pulse Count H/Over
This option allows zones from the same area that have
both pulse count and pulse count time programmed the
ability to hand over pulses to other pulse count zones
during their respective pulse count time. Only zones that
have an active pulse count time can accept pulse count
handover from another zone.
Burglary delay zones can only handover pulses to other
burglary delay zones. Burglary instant and/or handover
zones can handover pulses to other burglary instant and/
or handover zones. 24 hour non-fire zone types can only
MENU 2-1-2
Bosch Security Systems 07/14 BLCC610I
Y
Y
N
Y
N
N
N
N

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents