10 – Panic 24Hr
This zone type is used for a general type of emergency
including the presence of one or more unwanted persons
trying to gain entry to the premises. It will sound an
alarm at any time as soon as the zone becomes faulted
regardless of what state the area is in. A 24hr Panic report
will be sent to the central station receiver.
11 – Fire 24Hr
This zone type is used for Fire and Smoke detector
alarms. If the EOL configuration is set for a single EOL
value, the correct operation for fire zones are SHORT =
Alarm / OPEN = Trouble. For this to operate correctly, the
option 'Smoke Reset On Arming' needs to be disabled for
each area. A 24hr Fire report will be sent to the central
station receiver.
If a horn speaker is connected and programmed, a
distinct fire sound will be heard to indicate that it is a fire
alarm that has registered. The fire sound via the horn
speaker is different than the burglary sound.
All fire zones that have registered an alarm will continue
to display on all keypads until a fire reset has been
performed (see MENU 3-0-5), even if the fire zone input
has returned back to normal state. During this time, a
user will also be prevented the ability to turn the area on
or manually bypass the fire zone(s) until a fire reset has
been performed.
13 – Keyswitch Zone
A keyswitch zone can be used as an input terminal to
turn on and/or off an area. Refer to MENU 3-4-1 —
Keyswitch Options to select the various options such as
latching or momentary arm and/or disarm etc. When
reporting back to base, the keyswitch user number will
follow the actual zone number.
14 – Display Only
A display zone is not a burglary zone. It can never sound
the sirens or trigger the dialler. Its purpose is to only
display on the keypad when faulted.
15 – Non Burglary 24Hr
This zone type operates as a 24-hour type and is used for
non-specific alarms such as water level or temperature
sensors.
The 24 Hour Zone Types listed above are active
i
24hrs a day. They will trigger an alarm regardless of
Note
whether or not the system or area is in the Armed,
Part Armed or Disarmed state.
7-6
Input Programming
Inputs > Zone Properties >

Area Assignment

00 - No Area
01 - Security System
02 - Area 2 Name
03 - Area 3 Name
04 - Area 4 Name
This menu programs which area or partition each zone
belongs to. The system can be partitioned to a maximum
of 8 separate areas. Each zone can only be assigned to a
single area. For installations requiring a common access
point, it is possible to set Area 1 to be a common area. See
MENU 7-7-1 — Area Options
1) Press [MENU] + [3] + [1] + [2] and use the up and
down arrows to highlight the Zone in the list then
press [OK]. Alternatively, you can enter the zone
number directly and press [OK].
Area Assignment
01 - Security System
Press  0-9 OK to SAVE
2) Use the up and down arrows to select the area that
you want to assign the zone to.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
MENU 3-1-2
0 1
05 - Area 5 Name
06 - Area 6 Name
07 - Area 7 Name
08 - Area 8 Name
Zn1