Door Options; Hold Off If Area Armed; Hold Off Auto Unlock; Report Door Forced - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Outputs > Door Properties >

Door Options

1

Hold Off If Area Armed

2

Hold Off Auto Unlock

3
Reserved
4

Report Door Forced

5

Alarm Door Forced

6
Reserved
7
Reserved
8
Reserved
1) Press [MENU] + [4] + [2] + [3] and select the door
you want to program from the list then press [OK].
Alternatively, you can directly enter the door
number then press [OK].
2) Use the up and down arrow keys to highlight the
option, then press the [ON] key to enable or the
[OFF] key to disable.
 Hold Off If Area Armed
Hold Off Auto Unlock
Release On Fire Alarm
Press  OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Hold Off If Area Armed
This option when enabled and used in conjunction with
a timezone assigned under the door control menu will
stop the door from unlocking if the area behind the door
is armed. This is very useful in cases where the holiday
list may not have been kept up to date.
Hold Off Auto Unlock
This option when selected will delay the automatic
unlocking until a valid user has presented his card after
the timezone unlocking (gate opening) time..
Report Door Forced
This option when turned on will enable the Door Forced
Open event to be reported as an access event. It will
also appear in the keypad display as an alarm condition
identifying the door 'ALARM Door 1 Name' .
Alarm Door Forced
This otpion when turned on will enable the Door Forced
Open event to cause an alarm condition and sound the
alarm sirens. It will also appear in the keypad display as
an alarm condition identifying the door 'ALARM Door 1
Name' . To silence this alarm, you must enter a valid PIN at
the keypad.
Bosch Security Systems 07/14 BLCC610I
O U T P U T T E S T I N G
Outputs > Output Testing >
MENU 4-2-3

External Siren Test

Y
N
This menu allows you to test the operation of any output
N
programmed as event type 36 (External Audible) or Event
Type 36 (Fire Alarm) for 5 seconds.
N
N
N
1) Enter [MENU] + [4] + [9] + [0] and select the area
N
N
2) Any outputs programmed for event type 36 or 39 in
3) When the siren test is complete, the keypad will
4) Press [OK] to exit.
Solution 6000
Installation Manual
you want to test the external sirens in from the list
then press [OK].
A1 Security System
A2 Area 2 Name
A3 Area 3 Name
Press  OK or MENU
the chosen area will now operate. The keypad will
display the following during the siren test.
External Audible Testing
Press any key to abort
Press OK or MENU
display the following:
Testing Complete. Press
OK to continue
Press OK or MENU
Output Programming
-
MENU 4-9-0
8-13