programs which time zone to follow.
In previous versions, an output programmed to
i
follow any timezone (i.e. Event Type = 58 - TimeZone
Note
and Event Assignment = 00 - Any TimeZone), would
fail to operate when any timezone period triggered.
In version 2.14, this has been corrected so that the
output will now trigger correctly when any period for
timezones 2 to 16 is triggered.
In previous versions, an output programmed to
i
follow a timezone with the Block If All On option
Note
set in MENU 4-1-5, would continue to operate even
when any area was turned All On.
In version 2.14, this has been corrected so that the
output will not operate when any area has been
turned All On if Option 7 - Block If All On is set in
MENU 4-1-5.
59 – Temperature Hi/Lo
This event type will cause the output to operate when
the keypad temperature increases above the maximum
or falls below the minimum set temperature. The output
will reset when the temperature reads between the
maximum and minimum values.
See MENU 7-7-3 — Keypad Hi/Lo Temp in Section 11 -
System Programming
60 – Door
This event type will cause the output to operate when a
user assigned to the same door swipes their token. The
prox reader must be assigned to the same door group as
the output and user.
The Event Assignment is the Access Group Number.
61 - Door Open Too Long
This output will turn on when the control panel has
detected that the zone assigned to the door has not
returned to normal before the end of the door open too
long time.
70 - User Panic
The output will turn on when a user initiates a keyfob
panic emergency. The output will turn off when the area
has been turned All On or the output time parmeter has
finished.
71 - CLI Trigger
The output will turn on when the control panel has
detected an incoming call with a telephone number
programmed in Trigger Table 1 or Trigger Table 2.
i
Outputs configured to follow telephone numbers
programmed in the CLI Trigger Table 2, (MENU 6-5-
Note
5-1) would fail to operate if any of the CLI trigger
telephone numbers call the GSM module. In version
2.14, this has been fixed.
8-8
Output Programming
71 - GSM Signal Lost
The output is triggered whenever the radio is
not registered on the GSM network and restores
automatically on exiting programming mode or when
the radio resumes its connection with the network.
73 - GPRS Failure
The output is triggered when communication to
the GPRS network is lost and data can no longer be
transferred between the radio and the APN (Access Point
Name). It restores automatically on exiting programming
mode or once data transmission resumes between the
radio and the APN.
74 - Ethernet Fail
Bosch Security Systems 07/14 BLCC610I