Output Name; External Siren Test; Internal Siren Test - Bosch Solution 16i User Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

1.
Enter [Master PIN] + [MENU]
2.
Enter [4] + [0] + [1] + [OK]. The keypad will display
the Op= prompt which will flash indicating you
are in data entry mode. Any output(s) which are
currently on will also be displayed.
1
3
If your system is configured for multiple areas the
area Icon for the current area will also be displayed.
3.
Enter the output number you want to control, then
press [OK]. The output will operate. If the output
number is visable then the output will be on, and
if the output number is off then the coresponding
output is off.
4.
Repeat step 3 for any additional outputs that you
need to control.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Outputs > Properties >

Output Name

This menu allows the master user to program the output's
name. A maximum of 16 characters can be entered in this
field. Use the [←] and [→] keys to scroll the cursor left and
right to view the entire output name.
The text programming procedure is very similar to that of
most mobile phones. Refer the Programming Text section
on page 10 for more details.
Output names are stored with associated events in the
system's history log. This enables accurate auditing of
events at a later time if required. Names are also used when
reporting alarms and arm /disarm events in SMS and other
text based reporting formats.
Each output has a default name which can be changed if
desired. The default names are as follows.
D E FAULT OUT PUT NA MES
Output Number
1
2
3
4
5
6
7
8
Table 11: Default Output Names
Outputs 5 to 8 are available when the optional output
expander is fitted. Discuss this feature with your installer.
1.
Enter [Master PIN] + [MENU]
2.
Enter [4] + [1] + [0] + [OK]. The keypad will display
the Op = prompt. Enter the Output number you
want to program, then press [OK].
Bosch Security Systems 10/07 BLCC500U FTR1.01
Op=
1
OP AME
MENU 4-1-0
Default Name
E ternAl Siren
strobe
smoke sensor
InternAl Siren
Output 5 NAme
Output 6 NAme
Output 7 NAme
Output 8 NAme
3.
The keypad will display the current Output Name.
Use the [←] and [→] keys to view the existing
Output name. The cursor position is indicated by
the flashing character in the name. It is possible
to edit a single character in the name without re-
enetering the entire name.
4.
Use the 0 to 9, [←] and [→] keys to change the
Output Name text as required. At any time you
can use the [↑] and [↓] keys to scroll through the
complete list of available characters.
5.
To clear all text from the cursor position to the right,
press the [OFF] key.
6.
When the Output Name is complete, press [OK]
to save and exit, or press [MENU] to exit without
saving.
Outputs > Output Testing >

External Siren Test

This menu allows you to test the external sirens
which
have
been
The test will last for 5 seconds.
1.
Enter [Master PIN] + [MENU]
2.
Enter [4] + [9] + [0] + [OK]. If your system has been
configured to have more than one area, the keypad
will display the A = prompt.
Enter the Area number in which to test the external
sirens in and then press [OK].
3.
The sirens will now operate for 5 seconds and the
word Siren and the alarm ICON will be displayed on
the keypad.
ALARM
4.
The siren test will stop automatically after 5
seconds.
Outputs > Output Testing >

Internal Siren Test

This menu allows you to test any internal sirens which
have been connected to the system. The test will last for 5
seconds.
1.
Enter [Master PIN] + [MENU]
2.
Enter [4] + [9] + [1] + [OK]. If your system has been
configured to have more than one area, the keypad
will display the A = prompt.
Solution16
User Guide
i
Op=
Strobe
tStSir
MENU 4-9-0
connected
to
the
SiRen
TSTInT
MENU 4-9-1
system.
21