operate. For Example you may want a strobe output
to operate for 1 hour, Either of the examples below will
achieve the 1 hour time.
Total Time
Hour
60 Minutes
001
60 Minutes
000
Table 22: Example - Output One Shot Timer

Pulsing Mode

The time base is the unit of time that the output will pulse
on and off. If the time base is programmed for 60 seconds,
the output will pulse on for 60 seconds and then off for 60
seconds (repeat) until the output is reset.
Outputs > Properties >

Output Options

1
Off On Low Battery
2

Guest Control

3

Reserved

4

Monitor Overload

5

Monitor Device Fail

6

Alarm On Device Fail

7

Block If All On

8

Show Status On Keypad

1) Press [MENU] + [4] + [1] + [5] and select the output
you want to program from the list then press [OK].
Alternatively, you can directly enter the output
number then press [OK].
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
 Off On Low Battery
Guest Control
Reserved
Press  OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Off On Low Battery This option forces the control panel
not to operate the output when a low battery or missing
battery condition is in effect. Once the low battery
condition restores, the output will return to normal
operation.
Bosch Security Systems 07/14 BLCC610I
Minute
Seconds
10th Sec
000
000
000
060
000
000
MENU 4-1-5
Solution 6000
Guest Control
Guest control when enabled allows the output to be
controlled from the quick select menu on the keypad
which is a simple pull down menu. This allows you to
view and alter the state of the output without the need
of a PIN. To simply turn on or off guest control outputs,
press the [←] key.
Monitor Overload
Monitor Overload when selected will monitor the output
for an overload condition and display as well as report if
an overload condition occurs. The event will always be
logged regardless if enabled or not.
Monitor Device Fail
Monitor device fail when selected will monitor the
output for a disconnection condition and display as well
as report when a disconnection occurs.
Alarm On Device Fail
This option causes the panel to sound an alarm when
Y
the output device becomes missing (armed or disarmed
N
state).
N
Block If All On
Y
This option prevents the output from turning on when
Y
the corresponding area is turned All On. When the area
N
is off, Part On or Part 2 On, the output can again operate
N
when the output event occurs.
N
Show Status On Keypad
This option allows the keypad to display the output that
is currently active on the keypad.
Outputs > Properties >

Macro Group

Reserved
Installation Manual
Output Programming
MENU 4-1-6
8-11