ICP-VR8488 | Quick Reference Guide | 9.0
Location
309 to 322 (continued)
Zone #07 (Default = Instant)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone #08 (Default = 24 hr. Tamper)
Zone Type
Zone Pulse Count
Zone Pulse Count Time
Zone Options 1
Zone Options 2
Report Code
Dialer Options
Zone Types
Zone Type
Description
0
Instant
1
Handover
2
Delay 1
3
Delay 2
4
Reserved
5
Reserved
6
24-hour medical
7
24-hour panic
8
24-hour hold-up
9
24-hour tamper
10
Reserved
11
Keyswitch
12
24-hour burglary
13
24-hour fire
14
Chime
15
Not used
Zone Pulse Count
Use the pulse count to program the number of pulses
(0 to 15) that must register within the pulse count
time to activate an alarm.
Zone Pulse Count Time
Option
20 ms Loop
Response
Time
0
0.5 sec
1
1 sec
2
2 sec
3
3 sec
4
4 sec
5
5 sec
6
10 sec
7
15 sec
Bosch Security Systems, Inc. | 12/08 | F01U089640-01
Programming Guide
309
0
310
0
311
0
312
1
313
12
314
1
315
1
316
9
317
0
318
0
319
1
320
12
321
1
322
1
Option
150 ms Loop
Response Time
8
20 sec
9
30 sec
10
40 sec
11
50 sec
12
60 sec
13
90 sec
14
120 sec
15
200 sec
Zone Options 1
Option
Description
1
Lockout siren/dialer
2
Delay Alarm Report
4
Silent alarm
8
Sensor watch
Zone Options 2
Option
Group
1
Isolated in STAY Mode 1
2
Zone isolation allowed
4
Forced arming allowed
8
Zone Restore Report allowed
Zone Dialer Options
Option
Description
0
No Zone Reports allowed
1
Report to Receiver 1
2
Report to Receiver 2
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1 fails
Keyswitch Zone Options
The keyswitch zone options replace Zone Options 1
for zones programmed to operate as keyswitch zones.
Option
Description
0
Latching arm and disarm in AWAY Mode
1
Latching arm in AWAY Mode
2
Latching disarm from AWAY Mode or STAY
Mode
4
Latching arm and disarm in STAY Mode
5
Latching arm in STAY Mode
6
Latching disarm from STAY Mode
8
Momentary arm and disarm in AWAY Mode
9
Momentary arm In AWAY Mode
10
Momentary disarm from AWAY Mode or
STAY Mode
12
Momentary arm and disarm in STAY Mode
13
Momentary arm in STAY Mode
14
Momentary disarm from STAY Mode
Swinger Shutdown Count for Siren
379
Location
Default
3
1 to 15
Number of times siren operates until
lockout
Swinger Shutdown Count for Dialer
Location
380
6
Default
0
Unlimited
1 to 15
Number of times dialer operates until
lockout
EN | 20