Wiring Diagrams; Eol Resistor Colours And Values; Board Connectors; Terminal Descriptions - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

Solution 6000
Installation Manual
E O L R E S I S TO R CO LO U R S A N D VA LU E S
Use either the 4 colour, or solid colour resistors supplied.
3K3 =
6K8 =
Figure 21: EOL Resistor Colour Chart
B O A R D CO N N E C TO R S
T
he following table lists the various sockets, pin headers
and switches located on the panel and their functions.
Connector
This socket allow you to connect a service
Service
Keypad to the panel during installation.
This socket is used to connect the panel
Tamper
enclosure tamper switch.
This push button is used to reset the control
Default
panel back to factory default.
Voice
This is used to connect the optional Voice
Module
Command Module (CM101B).
This socket is used to connect serial devices to
Serial
the control system like a Serial STU.
This is a RJ12 6P/4C connector that allows
Telco
you to connect the control panel to the PSTN
telephone line.
The relay select PIN's allow you to easily
Relay
program the relay common contact to switch
either +12v or GND by fitting a plug on link.
Table 10:
Board Connector Descriptions
3-2

Wiring Diagrams

Orange
Blue
Description
T E R M I N A L D E S C R I P T I O N S
Name
Earth wire from this terminal is connected to
1
Earth
the Mains earth.
2
~ (AC)
Connection of the AC plug pack transformer
3
~ (AC)
4
BAT (-)
Negative and positive connections to the
5
BAT (+)
stand-by battery. 12 VDC / 7AH
6
+12 V
7
+12 V
8
+12 V
These terminals are used to power detectors
9
GND
and LAN devices up to 750 mA.
10
GND
11
GND
12
LAN +
These terminals are used to power LAN
13
LAN -
devices up to 750 mA.
Connect the LAN A data terminal of any LAN
device (eg. Keypads, expansion boards) to
14
LAN A
this terminal. The control panel supports up
to 300 m of 24/0.20 (18 AWG) wire on these
terminals.
Connect the LAN B data terminal of any LAN
device (eg. Keypads, expansion boards) to
15
LAN B
this terminal. The control panel supports up
to 300 m of 24/0.20 (18 AWG) wire on these
terminals.
Alarm power capable of providing a
16
COMM+
maximum of 2 Amp (+). This terminal is PTC
Fuse protected.
17
OUT 1
Programmable output, capable of providing
18
OUT 2
a maximum of 500 mA (-). This terminal is
19
OUT 3
PTC Fuse protected.
20
OUT 4
21
N/C
22
COM
2 A @ 24 VDC Relay Output - Form C contact
23
N/O
Programmable Input for RF Receivers,
24
INPUT
Keyswitch and other devices.
25
ZN 1
Zone 1 and 9 sensor loop input (+).
26
GND
Common (-) for Zone 1 and 2 sensor loop.
27
ZN 2
Zone 2 and 10 sensor loop input (+).
28
ZN 3
Zone 3 and 11 sensor loop input (+).
29
GND
Common (-) for Zone 3 and 4 sensor loop.
30
ZN 4
Zone 4 and 12 sensor loop input (+).
31
ZN 5
Zone 5 and 13 sensor loop input (+).
32
GND
Common (-) for Zone 5 and 6 sensor loop.
33
ZN 6
Zone 6 and 14 sensor loop input (+).
34
ZN 7
Zone 7 and 15 sensor loop input (+).
35
GND
Common (-) for Zone 7 and 8 sensor loop.
36
ZN 8
Zone 8 and 16 sensor loop input (+).
37
IN
These terminals are used to connect the
38
IN
telephone line from the street.
39
OUT
These terminals are used to connect the
40
OUT
premises telephones.
Table 11: Terminall Block Descriptions and Functions
Description
Bosch Security Systems 07/14 BLCC610I

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents