4) Press [OK] to save and exit or press [MENU] to exit
without saving.
A R E A T E S T I N G
Areas > Area Testing >

Area Watch

(*** System Wide Parameter ***)
This menu programs the number of weeks (001 – 255
weeks / 000 = disabled) an area can remain disarmed
before registering an 'Inactivity Interval' report. A restore
signal will be sent when the area is next armed and the
exit time expires.
1) Enter [MENU] + [2] + [9] + [0]. The keypad will
display the current number of weeks programmed
for area watch.
Area Watch
012 Weeks
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the number of weeks
that an area can remain turned off betore a trouble
condition will occur. Valid entries are 1 – 255
weeks or 000 to disable.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Area Testing >

User Test Interval

(*** System Wide Parameter ***)
This menu sets the number of days before it will prompt
the user to walk test the system. To clear the trouble
condition, you will need to perform the 'Walk Test' function.
1) Enter [MENU] + [2] + [9] + [1]. The keypad will
display the current number of weeks between user
test intervals.
User Test Interval
000 Days
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the number of days
between each user test interval. Valid entries are 1
– 255 days or 000 to disable.
3) Press [OK] to save and exit or press [MENU] to exit
without saving.
Bosch Security Systems 07/14 BLCC610I
Areas > Area Testing >

Service Interval

(*** System Wide Parameter ***)
MENU 2-9-0
This menu sets the number of weeks between service
0
1
2
intervals. When a service interval is due, a trouble condition
Weeks
will display on the keypad to remind the customer that a
system check is required by the security company. When
viewing the trouble condition, the keypad will display 'Call
For Service' . To clear the trouble condition, the installer
must enter and exit installer's programming mode.
1) Enter [MENU] + [2] + [9] + [2]. The keypad will
2) Using the numeric keys, enter the number of weeks
3) Press [OK] to save and exit or press [MENU] to exit
MENU 2-9-1
0
0
0
Days
Solution 6000
Installation Manual
display the current number of weeks between
installer service intervals.
Service Interval
000 Weeks
Press 0-9 OK to SAVE
between each service interval. Valid entries are 1 –
255 weeks or 000 to disable.
without saving.
Area Programming
MENU 2-9-2
0
0
0
Weeks
6-11