Incoming Call; System Trouble; Box Tamper; Zone Trouble - Bosch solution 6000 Installation Manual

Hide thumbs Also See for solution 6000:
Table of Contents

Advertisement

15 – Incoming Call
This event type will cause the output to operate when
the panel detects an incoming call on the phone line and
will reset when the ring signal stops.
16 – System Trouble
This event type will cause the output to operate when
the panel detects a system trouble condition and will
reset when the condition is cleared.
17 – Box Tamper
This event type will cause the output to operate when
the panel detects that the onboard cabinet tamper
circuit is open. The output will reset when the tamper
circuit is closed. No EOL resistor is required on this input.
18 – Zone Trouble
This event type will cause the output to operate when
the panel detects that a zone has a trouble condition and
will reset when the trouble condition has cleared.
19 – Zone Mirror
This event type will cause the output to operate when a
specific zone is open or unsealed and will reset when the
zone closes.
See MENU 4-1-2 — Event Assignment for infomation on
how to set the zone to mirror.
20 – Zone Alarm
This event type will cause the output to operate when a
specific zone has triggered an alarm and will reset when
the corresponding area is disarmed. For a non 24hour
zone to trigger an alarm the area must be armed. See
MENU 4-1-2 — Event Assignment for infomation on how
to set the zone to monitor.
21 – Area Disarmed
This event type will cause the output to operate as soon
as the corresponding area is disarmed and will reset
when the area is armed in either the All On or Part On
modes.
If the output event assignment for this output is set to
zero (all areas), then all areas must be disarmed for the
output to operate. The output will reset as soon as any
area is armed in either the All On or Part On modes.
22 – Area Part Or All On
This event type will cause the output to operate when
the selected area is armed in either All On or Part On
mode. The output will reset when the area is disarmed.
If the event assignment for this output has been set to
zero (all areas) then the output will only operate when all
areas have been armed in All On or Part On mode. The
output will reset as soon any area is disarmed.
Bosch Security Systems 07/14 BLCC610I
Solution 6000
Installation Manual
23 – Area All On
This event type will cause the output to operate as soon
as a specific area is armed All On mode and will reset
when the area is disarmed.
If the event assignment for this output has been set to
zero (all areas), then the output will only operate when
all areas have been armed in the All On mode and will
reset as soon as any area is disarmed.
24 – Area Part On
This event type will cause the output to operate as soon
as a specific area is armed Part On mode and will reset
when the area is disarmed.
If the event assignment for this output has been set to
zero (all areas), then the output will only operate when
all areas have been armed in the Part On mode and will
reset as soon as any area is disarmed.
25 – Area Part 2 On
This event type will cause the output to operate as soon
as a specific area is armed Part 2 On mode and will reset
when the ares is disarmed.
If the event assignment for this output has been set to
zero (all areas), then the output will only operate when
all areas have been armed in the Part 2 On mode and will
reset as soon as any area is disarmed.
26 – Entry Timing
This event type will cause the output to operate while
either Entry Timer 1, Entry Timer 2 or the Part Mode Entry
Timer is active. The output will reset when the entry
timer expires or the corresponding area is disarmed.
27 – Exit Timing
This event type will cause the output to operate while
Exit Timer is active. The output will reset when the exit
timer expires or the corresponding area is disarmed.
28 – End Of Exit Time
This event type will cause the output to operate
when the Exit Time expires and will reset when the
corresponding area is disarmed.
29 – Chime On
This event type will cause the output to operate when
Chime Mode is activated and will reset when Chime
Mode is turned off.
If the event assignment for this output is set to zero (all
areas), then the output will operate as soon as Chime
Mode is activated in any area and will reset when Chime
Mode is turned off in all areas.
30 - Chime Zone Trigger
This event type will cause the output to operate when
a specific Chime Zone is triggered and reset when the
Chime Zone reseals.