Outputs > Commands >

Turn Output On/Off

This command allows you to manuallly turn any output
ON or OFF. Outputs can be configured to control various
functions including outside lighting, pool pumps,
watering systems, air conditioners etc.
1) Press [MENU] + [4] + [0] + [1] and select the output
you want to operate from the list then press [OK].
Alternatively, you can directly enter the output
number then press [OK].
2) The keypad will display the following when the
output is off. To turn the Output On, press [ON]. To
override any time parameters that the output has
set, press and hold the [ON] key.
External Siren Op1
Output is OFF,
To turn ON, Press ON.
To Go Back Press OK
3) The keypad will display the following when the
output is on. To turn the output Off, press [OFF].
External Siren Op1
Output is ON,
To turn OFF, Press OFF.
To Go Back Press OK
4) Press [OK] or [MENU] when finished.
Outputs > Commands >

Output Array

This menu allows the master user and installer to view
output status in groups of 16. Outputs will continuously
be updated during the display so that real time status can
be seen. The top two rows of the display show the output
number, the third row displays the output status
N = NORMAL - Off Condition
T = TRIGGERED - On Condition
F = FAULT - Overload Condition
- = DISABLED
1) Enter [MENU] + [4] + [0] + [2] and use the up and
down arrows to select the output group to view.
2) Use the up and down arrows at any time to move to
a new group. The keypad will display the following
output array information for outputs 1 to 16.
0000000001111111
1234567890123456
NNNNN---TF------
Press  OK or MENU
8-2
Output Programming
-
-
MENU 4-0-1
-
MENU 4-0-2
In the above example screen,
N = Outputs 01 to 05 are Normal (Off )
F = Output 10 has a Fault (Overload)
T = Output 09 is Triggered (On)
- = Outputs 05 to 08 and Outputs 11 to 16 are
Disabled or Not Available
3) The keypad will display the following output array
information for outputs 17 to 32.
1112222222222333
7890123456789012
----------------
Press  OK or MENU
4) The keypad will display the following output array
information for output 33 to 40.
3333333444444444
3456789012345678
--------
Press  OK or MENU
5) When finished press [OK] or [MENU] to exit.
Outputs > Commands >

Door Status

This menu allows you to view the status of a selected door.
1) Enter [MENU] + [4] + [0] + [3].
2) A list of available doors will display on the keypad.
Dr1 Front Door
Dr2 Computer Room
Dr3 Warehouse Door
Press , OK or MENU
3) Use the [] and [] keys to select the door that you
want to check the status of, then press [OK] to
select. Alternatively, you can enter the door
number then press [OK].
The keypad will display the following:
Front Door Dr1
Door Locked
Press OK or MENU
4) The following door states can be displayed in the
door status menu.
Door Locked
Door Unlocked
Door Open By TimeZone
Door Manually Open
Door Forced Open
-
MENU 4-0-3