Solution 6000
Installation Manual

PIN Always Required

Setting this option will force the system to request a
valid PIN to be entered before any menu functions can
be accessed. If this option is not set then some restricted
menu options will be available without entering a valid
PIN.

Display Menu Numbers

Setting this option causes the keypad to display
the menu numbers for all commands and menu
programming options. The menu numbers can be used
as navigation shortcuts when programming.
System > System Options >

Area Options

1

Area 1 Common

2

First Open Last Close

3

Reset Siren All Users

4

Power Up As Down

5

Fault ACK All Areas

6

Delay Trouble Beeps

7

Power Up Disarmed

8

Ignore Trouble On Arm

(*** System Wide Parameter ***)
This menu allows you to configure the Area system
options. All options are global to users, areas and
keypads.
1) Press [MENU] + [7] + [7] + [1]. The keypad will
display the current Area system options.
Area 1 Common
First Open Last Close
 Reset Siren All Users
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Area 1 Common
Setting this option will cause the system to automatically
arm Area 1 All On when all other areas have been turned
on. As soon as any area is turned off the system will
automatically turn Area 1 off. Only one common area is
available on the system. If no common area is required
then do not set this option.
11-14
System Programming
MENU 7-7-1
N
N
Y
Y
Y
Y
N
N
First Open Last Close
Setting this option will cause the system to only report
an opening signal to the base station when the first area
is Disarmed and a closing signal when the last area has
been armed or turned All On.
Reset Siren All Users
Setting this option allows a user with a valid PIN to
silence alarm outputs from any keypad on the system
without the need to toggle the keypad to the area that
the alarm occurred.
If this option has not been programmed, the user will
need to toggle the keypad to the area the alarm occurred
in and then silence the alarm by entering their PIN
followed by the [OFF] key.
Power Up As Down
Setting this option will cause the panel to power up
in the same state as it was when it was powerd down.
For example with this option set if the panel is in the
disarmed state and all power is removed for service
work to be done. When the power is reapplied, the
panel will start in the disarmed state. Any zone that was
programmed as bypassed when the power was removed
will remain bypassed when the power supply has
restored.
If this option is not programmed, the system will always
power up in the armed All On state and any zones
bypassed prior to power loss will power up as un-
bypassed zones.
Fault ACK All Areas
Setting this option allow system trouble faults to be
acknowledged from any area or keypad on the system
without the need to toggle over to the area the fault
occurred in.
Delay Trouble Beeps
Setting this option will prevent any system trouble
events from sounding the keypad speaker between
the hours of 10pm until 7am. During this time, any new
trouble events will be shown in the keypad display.
If any trouble events are still in effect at 7am, the keypad
will begin sounding the trouble alert to notify the user
of the problem. The function is primarily for use in
residential installations.
Power Up Disarmed
Setting this option will allow the control panel to always
power up in the disarmed state after removing both the
battery and AC mains supply and then reapplying power.
Ignore Trouble On Arm
This option allows the control panel to ignore unsealed
zones and trouble conditions when a user arms an area.
Low battery conditions cannot be ignored and will
require the users input.
Bosch Security Systems 07/14 BLCC610I

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents