he control panel has 8 different areas each with its own
specific programmable options.
Under the commands menu you can interrogate the
status of an area, turn chime mode on/off, move to an area
or arm and disarm a specific area.
The customer account number is programmable for
each individual area as well as input, output and general
options. Each time you are presented with an option that
is area specific, the menu will prompt you to specify the
area first.
Partitioning
The control system can be partitioned into 8 individual
areas. Each area has its own individual properties which
determine how the area operates. The default name for
Area 1 is "Security System" and it can be changed to any
other name using the area properties menu. All zones and
users are assigned to Area 1 so no assigning of users or
zones is required for non partitioned systems by default.
To create an area, assign one or more zones to the area
of your choice. A zone can only belong to one area and
any number of zones can belong to a single area. Each
area operates independently from other areas as if it were
another security panel and there are numerous options
available to tailor just how the entire system should
operate. If you require a common area that automatically
arms when all other areas are armed, and disarms as soon
as any other area is disarmed, then Area 1 can be set as
a common area. To make area 1 a common area, set the
option under MENU 7-7-1 — Area Options.
All keypads connected to the system have the ability to
display the arm/disarm condition of every area at the same
time using the area icons on the display. This is selectable
per keypad under MENU 6-1-5 — Indicator Options.
Once you log onto a keypad using your [PIN] + [OK] the
system knows who you are and will allow you to use
the left arrow key to move from the current area to the
next area that your assigned to. To move areas without
having to enter your PIN select the option under MENU
6-1-2 — Area Options and then simply step through all
the available areas using the arrow keys. Each keypad is
assigned a home area and will automatically revert back
to this area after 60 seconds.
Bosch Security Systems 07/14 BLCC610BI

Area Programming

The system outputs must be configured to operate for
their corresponding areas. The external siren, internal
siren and strobe outputs are defaulted to output index 0
and will operate for any area.
Example: Simple Two Area System
1) Assign zones to area 1 and area 2
2) Assign the home areas for the keypads.
3) Assign users to areas.
4) Set outputs to operate individually or common for
all areas.
5) Set account number for each area.
6) Set options,
PIN to change areas or just arrow keys.
Which keypads to display area icons.
Reset sirens by any user on any area.
A R E A CO M M A N D S
Areas > Commands >

Area Status

This command allows you to view the condition of any
area in the system. In the following example, Area 1
has the name "Security System" and it is currently in the
disarmed state.
1) Enter [MENU] + [2] + [0] + [0] and select the area to
view and press [OK].
Security System A1
Disarmed
Press OK or MENU
The keypad will display the following states:
Disarmed - when the area is turned off.
Armed All On - when the area has been turned All On.
Armed Partial - when the area has been turned Part On.
Armed Part 2 - when the area has been turned Part 2 On.