Report PIN Retry

When the PIN retry count as programmed in MENU 1-5-1
is reached, a 'Wrong Code Entry' alarm report will be sent
to the control room.

Report Exit Error

This option allows the system to report an 'Exit Error'
alarm report.
An exit error occurs when an entry/exit delay zone
becomes unsealled during exit delay time and remains
unsealled at the end of exit delay time. If this happens,
the entry delay will start. If the area is not turned off
(disarmed) before the entry delay time expires an 'Exit
Error' alarm report will be sent.
Smart Lockout
Smart lockout allows a previously locked zone to
reactivate during the siren run time when a new alarm
event occurs.

Cancel Report

When set, a 'Cancel' report will be sent if a user disarms
the area before the siren timer expires.

Op/Cl In Part On

When set, the panel will send 'Open' or 'Close' reports
when the area has been turned Part On or Part 2 On.

Op/Cl After Alarm

When set, the panel will only send an 'Open' or 'Close'
report after an alarm has occured. This report will be sent
for all users regardless of whether or not they have been
programmed to send open/close reports.
6-6
Area Programming
Areas > Area Properties >

Strobe Trigger

1

Audible Burglary

2

Silent Burglary

3

Fire Alarm

4

Keyfob On/Off

5
Keyswitch On/Off
6
Reserved
7
24Hr Alarm
8
Reserved
Programming any of these options allow the strobe
output to operate when the corresponding event
occurs. The strobe light must be connected to an output
programmed as a event type 48 for it to operate. See
Section 8 — Output Programming for more information
on output event types.
1) Enter [MENU] + [2] + [1] + [5] and select the area
from the list then press [OK].
2) Use the up and down arrow keys to highlight the
option then press the [ON] key to enable or the
[OFF] key to disable.
 Audible Burglary
Silent Burglary
 Fire Alarm

Press
OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Audible Burglary
When selected, the panel will activate the strobe output
when an audible burglary zone has triggered an alarm.
Silent Burglary
When selected, the panel will activate the strobe output
when a silent burglary zone has triggered an alarm.
Fire Alarm
When selected, the panel will activate the strobe output
when a zone programmed as fire (audible or silent) has
triggered an alarm.
Keyfob On/Off
When selected, the panel will activate the strobe output
for six seconds when a user turns the area on via an RF
keyfob. This provides silent feedback to the user that the
signal has been received.
MENU 2-1-5
Bosch Security Systems 07/14 BLCC610I
Y
N
Y
N
N
N
Y
N