    Notice to O wner Thankyou for selecting the Solution 64 Security Control Panel for your security needs. Your system includes many advanced features and functions which will be programmed and configured by your security consultant during installation. Depending on the configuration, and your access level, you may have the ability to program certain features within the system to suit changes in your security needs.
  • Page 3: Table Of Contents

    Solution 64 User Guide Conte nts Copyright Notice ............2 Internal Siren Test ..........20 Trademarks ..............2 Strobe Test ............. 20 Notice of Liability ............2 Communication / Reporting ........21 Notice to Owner ............2 Call/Answer RAS ............ 21 Telepermit Note ............
  • Page 4: Program Menu Tree

    Holidays Periodic Test 7-6-0 Name 5-9-0 Send Test Report 7-6-1 Start Stop Dates System Options 7-7-3 Keypad Hi/Lo Temp System Testing 7-9-0 Walk Test All Zones 7-9-1 Battery Test Table 1: Control Panel Menu Tree Bosch Security Systems 09/06 BLCC110U...
  • Page 5: Introduction

    When you turn your system on, you have the option of turning Listed below are the main features of the Solution 64 control on all zones (All On), or just some of the zones (Part On). Refer panel.
  • Page 6: Reporting Alarms

    The area is turned Part On. The [↑] key allows you to navigate through The area is not turned Part On. menus or to toggle characters when programming telephone numbers. Bosch Security Systems 09/06 BLCC110U...
  • Page 7: Keypad Tones

    Solution 64 User Guide Icon Status Meaning After you turn an area All On, the keypad will sound 1 short beep every second. During the last Exit The area is turned off. Delay 10 seconds fast short beeps will be heard. If you Tone don’t exit before the delay time expires and an...
  • Page 8: Basic System Operation

    Turning An Area All On entry door to prevent an alarm. Opening a designated door (e.g. Use this function to turn an area All On. The Solution 64 control front door) will start entry time. During entry time, the keypad panel is factory default only for one area.
  • Page 9: Remote Arming - Quick Arm

    Solution 64 User Guide Remote Arming - Quick Arm sounds, try a different PIN. The keypad will now prompt you to enter your new PIN again. If you forget to arm your system it may be possible for you to remotely arm it using a touch tone telephone if the remote arm Confirm New PIN for...
  • Page 10: Change Other Pin

    , OK or MENU  Use the [] and [↓] keys to select the user that you want to add a PIN, then press [OK] to select. Alternatively, you can enter the user number you want Bosch Security Systems 09/06 BLCC110U...
  • Page 11: Tokens

    Solution 64 User Guide Tokens 1. Enter [MENU] + [1] + [2] + [1]. A list of users will display on the keypad. This section outlines how to add and delete token cards that allow an alternate method for users to turn the system on and Use the [] and [↓] keys to select the user who’s token you...
  • Page 12: Delete Keyfob

    Timer Groups are used to restrict users from operating doors U003 USER 3 NAME outside given times, days or holidays. To do this you need to Press OK or MENU  create a time group, then assign one or more schedules to the Bosch Security Systems 09/06 BLCC110U...
  • Page 13: Timer Group

    [MENU] to exit without saving. Areas Access > User Properties > The Solution 64 control panel has the ability to be partitioned Timer Group MENU 1-4-4 up to 8 individual areas. This section outlines various commands that control individual areas.
  • Page 14: Turn Area On/Off

    [OK]. 1. Enter [MENU] + [2] + [0] + [2]. The keypad will display the exit time bar to prompt you to exit all areas. You should leave all areas now. Bosch Security Systems 09/06 BLCC110U...
  • Page 15: Chime On/Off

    16 characters. At when the corresponding area is turned off (disarmed). This can factory default, only Area 1 is used. The Solution 64 control panel be useful when you need to monitor the front or back entrance can have a maximum of 8 independent areas programmed.
  • Page 16: Bypass Zones

    4. Press [OK] to save and exit, or press [MENU] to exit when chime mode is turned on. without saving. 5. Press [OK] to save and exit, or press [MENU] to exit Repeat steps 1 to 4 to bypass or un-bypass additional without saving. zones. Bosch Security Systems 09/06 BLCC110U...
  • Page 17: Set Part 2 Zones

    Solution 64 User Guide Inputs > Commands > Inputs > Commands > Set Part 2 Zones Smoke Sensor Reset MENU 3-0-4 MENU 3-0-5 This menu allows you to program which zones are to be monitored This menu allows you to reset smoke sensors.
  • Page 18: Walk Test All Zones

    Selected zones have been Outputs Tested OK The Solution 64 control panel has up to a maximum of 8 outputs. 4 outputs are available as standard with an additional 4 available Press OK or MENU when the optional output expander is fitted. Your installer will advise you on the exact makeup and configuration of you...
  • Page 19: Turn Output On/Off

    Solution 64 User Guide Output 1 Name O001 Output 1 Name O001 Is Off and Ready Output is OFF, To Turn ON,Press ON. To Go Back Press OK Press OK or MENU To turn the output on, press [ON]. The keypad will display the following when the output is off...
  • Page 20: External Siren Test

    2. Use the [↑] and [↓] keys to select the area that you want to test the bell, then press [OK]. Alternatively, you can enter the area number, then press [OK]. The keypad will display the following during the bell test. Bosch Security Systems 09/06 BLCC110U...
  • Page 21: Communication / Reporting

    If the user fails to acknowledge the This menu allows you to initiate a modem call to the installer’s call, the Solution 64 control panel will make another attempt to off-site computer for programming changes or updates. Your report until the maximum number of call attempts are reached.
  • Page 22: Call Forward On Number

    These addresses allow you to program the Call Forward Off 6. Using the numeric keys, enter all the digits of the third sequence that the Solution 64 control panel will automatically telephone number (if required). use when you turn Area 1 ‘Off’ .
  • Page 23: Send Test Report

    MENU 5-9-0 Keypad 001 Kp001 This menu allows you to test the reporting functions of the Solution 64 control panel by manually sending a ‘Test’ report to Graphic + Prox V1.01 the receiving party (i.e. security company monitoring station, Volts = 13.87 mobile telephone etc).
  • Page 24: Backlight

    The System Trouble Menu displays all current system troubles trouble events and their meanings. in a list format. Some trouble events require you to drill down and non-system trouble that are curent within the Solution 64 control panel. Enter programming mode (PIN + MENU) then, 1.
  • Page 25 Solution 64 User Guide Trouble Condition Description The system has detected that the AC mains supply has failed or is disconnected. If there is not a general power outage Mains Missing in your area then you should contact your security company.
  • Page 26: History Log

    MENU 7-5-1 This menu allows you to program/adjust the date and time in the This menu allows you to program both the start time and stop Solution 64 control panel. time of each schedule. Enter programming mode (PIN + MENU) then, Enter programming mode (PIN + MENU) then, 1.
  • Page 27: Day

    Solution 64 User Guide 3. Enter the new start and stop times in 24-hour format Use the [] and [] keys to scroll through the different (00:00 to 23:59 hours). characters available. To clear all text from the cursor position to the right, press the [OFF] key.
  • Page 28: Walk Test All Zones

    MENU 7-9-1 This menu allows you to manually test the systems back up battery. The Solution 64 will automatically test the battery once per day and every time the system is armed. The battery test can take up to two minutes to complete and the keypad will display the voltage of the battery during the test.
  • Page 29: Installation Details

    Solution 64 User Guide I n st al lat io n Details INSTALLED BY: DATE PHONE: FAX: EMAIL: SERVICE PHONE: FAX: EMAIL: MONITORED BY: PHONE: FAX: EMAIL: WARRANTY EXPIRES: NOTES: Bosch Security Systems 09/06 BLCC110U...
  • Page 30: Index

    Time ................... 26 Holidays Security System Basics Naming Holidays ..............27 Are All Zones The Same? ............ 5 Set Start/Stop Times ............27 What Is A Faulted Zone ............5 What Is A Zone ..............5 Bosch Security Systems 09/06 BLCC110U...
  • Page 31 Solution 64 User Guide Service Required ..............25 Silencing Alarms ............... 8 Silent Alarms ................9 Smoke Detectors Sensor Reset ............... 17 Status Area ................... 13 Keypad ................23 System Date/Time ................26 History Log ................. 26 Holidays ................27 Schedules ................
  • Page 32 Bosch Security Systems 25 Huntingwood Drive Huntingwood, NSW 2128 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2006 Bosch Security Systems BLCC110U 920304 Issue FTR1.2...

Table of Contents