Inputs > Zone Properties >
Zone Type

00 - Not Used

01 - Burglary Delay 1

02 - Burglary Delay 2

03 - Burglary Instant

04 - Burg Inst No Exit

05 - Burg Handover

06 - Burglary 24Hr

07 - Tamper 24Hr

08 - Hold Up 24Hr

This menu allows you to configure the zone type or
behaviour for every zone in the system. Each zone should
be assigned to a Zone Type that defines the way in which
the panel will respond when an alarm is triggered on that
zone. Refer to the table and descriptions below for the
available Zone Type selections.
1) Press [MENU] + [3] + [1] + [1] and use the up and
down arrows to highlight the Zone in the list then
press [OK]. Alternatively, you can enter the zone
number directly and press [OK].
2) Use the up and down arrow keys to select the Zone
Type required then Press [OK] to save and exit or
press [MENU] to exit without saving.
Zone Type Zn1
01 - Burglary Delay 1
Press  0-9 OK to SAVE
00 – Not Used
Program the zone type as zero if the zone is not being
used.
01 – Burglary Delay 1
Zones programmed as Delay 1 will cause Entry Timer 1 to
start when tripped. The user must disarm the area before
entry timer expires or an alarm will occur. Zones set as
Burglary Delay 1 are only active when the area is armed.
See MENU 7-2-1 — Entry Time 1 to set the required delay
time.
02 – Burglary Delay 2
Zones programmed as Delay 2 will cause Entry Timer 2 to
start when tripped. The user must disarm the area before
entry timer expires or an alarm will occur. Zones set as
Burglary Delay 2 are only active when the area is armed.
See MENU 7-2-2 — Entry Time 2 to set the required delay
time.
03 – Burglary Instant
Zones programmed as Instant 1 will immediatly cause
the alarm to trigger when the zone is tripped. ie No Entry
Delay. Zones set as Burglary Instant 1 have Exit Delay and
are only active when the area is armed. See MENU 7-2-0
Bosch Security Systems 07/14 BLCC610I
MENU 3-1-1
0 1

09 - Medical 24Hr

10 - Panic 24Hr
11 - Fire 24Hr
12 - Not Used
13 - Keyswitch Zone
14 - Display Only
15 - Non Burglary 24Hr
Solution 6000
Installation Manual
— Exit Time
04 – Burg Inst No Exit
Zones programmed as Instant 2 will immediatly cause
the alarm to trigger when the zone is triggered. ie. No
Entry Delay. Zones set as Burglary Instant 2 have NO Exit
Delay and are only active when the area is armed.
05 – Burglary Handover
A Handover zone will provide a delayed alarm only when
a delay zone has been tripped first (ie. the entry time is
active) otherwise it will trigger an instant alarm.
Zones programmed as Handover can be set to sequential
or non-sequential handover. At factory default, handover
is set to sequential which means that zone must be
triggerred in numerical order for the delay to handover.
Non Sequential Handover means the zone do not have
to be programmed in numerical order. In both cases an
entry delay zone must be triggered first for the delay to
handover.
See MENU 2-1-2 — Input Options to set Non Sequential
Handover.
The Zone Types listed above will only trigger an
i
alarm if the system or area is in the armed state
Note
and the exit time has exprired. Zones must be
sealled at the end of exit time to trigger alarms.
06 – Burglary 24Hr
Zones programmed as 24-hour burglary will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. 24-Hour zones are active 24
hours a day. A 24hr Burglary report will be sent to the
central station receiver.
07 – Tamper 24Hr
Zones programmed as 24-Hour Tamper will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. 24-Hour zones are active 24
hours a day. A 24hr Tamper report will be sent to the
central station receiver.
08 – Hold Up 24Hr
Zones programmed as 24-Hour Hold Up will trigger
a Silent alarm as soon as the zone becomes faulted
regardless of what state the area is in. 24-Hour zones are
active 24 hours a day. A 24hr Hold Up report will be sent
to the central station receiver. No Siren/Strobe or Keypad
indication will be given. To view the status of a 24hr hold
up zone, refer to MENU 3-0-1.
09 – Medical 24Hr
This zone type is used for personal medical emergency
alarms. Zones programmed as 24-Medical will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. A 24hr Medical report will be
sent to the central station receiver.
Input Programming
7-5