Auto Exit Install 2hr

Setting this option will cause the panel to automatically
terminate Installer programming mode after 2 minutes
of no activity on the keypad. If this option is not set, the
panel will remain in Installer programming mode until
manually terminated.

Auto Exit Service 2hr

Setting this option will cause the panel to automatically
terminate service mode after 2 hours of no activity
on the keypad keys. If this option is not set, the panel
will remain in the service mode until it is manually
terminated.

Multi Tenant Mode

This options includes additional support for muti tenant
applications such as self storage garages or scholl
storage lockers etc.
When enabled, the option will lock the first 144 users on
the system to each of the 144 zones on the system. Each
time the users enters their PIN + [OFF], the corresponding
zone is automatically bypassed allowing them to access
the zone area. The zone is again ready to detect intrusion
when the user enters their PIN + [ON].
Users 145 to 255 continue to operate as normal users.

Allow Defaulting

Setting this option will allow the panel to be defaulted
back to the factory setting using the the on board push
button switch. See below for defaulting instructions.
If this option is not set then manual defaulting will not
function and the only way to default the panel will be by
using the current installer PIN. If the installer PIN is not
know then the panel will need to be returned to Bosch
Security for defaulting. A charge applies for this service.
Defaulting the panel does not erase all events in the
i
history event log. If this option has been disabled,
Note
the dialler seize relay will pulse or click 4 times during
power up.
11-16
System Programming
System > System Options >

Language

0 - English
1 - Alternate Language
This menu allows you to select the language that will be
displayed on the keypad. You have a choice between
English (default) or a second language (determined by the
country that the control panel is shipped to).
1) Enter [MENU] + [7] + [7] + [5]. The keypad will
display the following:
Language
0
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the language option
as required then press [OK] to save and exit or press
[MENU] to exit without saving.
System > System Options >

Site Name

1
M y
A
l
This menu allows the master user to program the emails
subject line to identify the alarm system (eg. site name) to
the receiving party. A maximum of 32 characters of text
can be entered in this field. Use the [] and [] keys to
scroll the cursor left and right to view the entire name.
1) Enter [7] + [7] + [7] + [OK].
The keypad will display the current Site Name.
Site Name
MyAlarm


Press
2) Using the numeric keys, enter the description of the
control panels site name. You can change a single
chanracter by scrolling the cursor left [] and right
[].
At any time you can use the [] and [] keys to scroll
through the complete list of available characters.
To clear all text from the cursor position to the right,
press the [OFF] key.
3) When the site name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
MENU 7-7-5
-
MENU 7-7-7
Characters
a
r m
OK to SAVE