View Point Trouble (Cmd 48); System Test (Cmd 41) - Bosch D623 User Manual

Hide thumbs Also See for D623:
Table of Contents

Advertisement

Security System
User Guide

View Point Trouble (Cmd 48)

Use this command to view any points (if any) that are in trouble.
1.
Ensure the system is turned off (On indicator is off).
2.
Press [CMD] [4] [8]. The command center may prompt you to enter a valid passcode.
3.
Enter your passcode if necessary. The command center scrolls through all points in trouble.
Be sure to investigate the source of the trouble condition. Correct the condition if possible. For example,
remove objects blocking a sensor point or respond appropriately to the trouble indicated.
If there are no points in trouble, the command center displays:
4.
Press [CMD] to return to the normal display.

System Test (Cmd 41)

I can perform this command.
I cannot perform this command.
The System Test ensures your system is operating correctly by testing the system's bell, strobe, battery, and phone line. Only
those programmed by your installing security company will be tested. For example, the system may only be programmed to
test the back-up battery and the bell output.
I can test:
System Bell
System Strobe
If any of these components fail to test, contact your security company for assistance. Be sure to contact your security
company before you begin the system test.
1.
Make sure the system is turned off (On indicator is off).
2.
Press [CMD] [4] [1]. The command center may prompt you to enter a valid passcode.
3.
Enter your passcode if necessary. The system starts the test. The bell output is tested first and should
sound for approximately 2 sec. to 3 sec. The display shows:
4.
Listen for bell activation.
The strobe output is tested next. This test resets after approximately 20 min. or when [*] is pressed.
5.
Check for strobe activation.
The next component to be tested is the back-up battery. This test may take up to 4 min.
The command center displays the result of the battery test:
46841D
There are no
point troubles.
Battery
Phone Line
Testing Bell.
Testing Strobe.
Press * to End
Testing Battery
May take 4 min.
Battery Test
passed.
D623/D625 User Guide
Battery Test
failed!
or
Please call for
service.