If the zone is programmed for Part 2, the keypad will
prompt:
Zone 1 Name Zn1
Is armed in Part2.
To remove, Press OFF.
To Go Back Press OK
4. Press [ON] to monitor the zone when the area is
turned Part 2 On, or press [OFF] so that you do not
monitor the zone when the area is turned Part 2 On.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Inputs > Commands >

Smoke Sensor Reset

This menu allows you to reset smoke sensors.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [0] + [5].
A list of different areas will display on the keypad.
2. Use the [] and [] keys to select the area that you
want to reset the smoke detectors, then press [OK]
to select. Alternatively, you can enter the area
number, then press [OK].
The keypad will display the following:
Smoke Detector reset in
progress. Please wait
3. The keypad will automatically return to the menu
when all smoke detectors in the area has been reset.
Inputs > Zone Properties >

Zone Name

This menu allows you to program up to 20 characters for
the name of each zone.
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [3] + [1] + [0].
A list of different zones will display on the keypad.
2. Use the [] and [] keys to select the zone name
that you want to change, then press [OK] to select.
Alternatively, you can enter the zone number, then
press [OK].
The keypad will display the following:
24
3. Use the [] and [] keys to scroll the cursor left and
right across the zone name text. Use the [] and
[] keys to scroll through the different characters
available. To clear all text from the cursor position
to the right, press the [OFF] key.
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Inputs > Input Testing >

Walk Test All Zones

This menu allows you to test all zones within an area at the
same time. To successfully walk test each zone, you must
open and close each zone.
Enter programming mode (PIN + MENU) then,
MENU 3-0-5
1. Press [MENU] + [3] + [9] + [0].
The keypad will display a list of areas that are
available to walk test zones.
2. Use the [] and [] keys to select the area that you
want to do walk test, then press [OK] to select.
Alternatively, you can enter the area number, then
press [OK].
The keypad will scroll all zones that you can test.
3. Open and close each zone that needs to be tested.
A zone that has been successfully tested will no
MENU 3-1-0
longer scroll on the keypad display.
When all zones have been tested, the keypad will
display:
4. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Zone Name Zn1
Zone 1 Name
Press
OK to SAVE


To test zone Zn1
open then close
Zone 1 Name
Press OK or MENU
To test zone Zn2
open then close
Zone 2 Name
Press OK or MENU
All zones have been
successfully tested
Press OK or MENU