Function Test for the SPE Blocking Element and Reader
Switching on the power supply
Make sure that bridge B1 on the control unit is connected before switching on the power sup-
ply.
Switch on the power supply.
The yellow LED on the control unit's circuit board displays the system's status as follows:
Yellow LED
Status
Off
System is OK
On
Electronic defect.
Function test
1. Remove the jumper from B1 and plug it into B3 on the control unit.
The SPE blocking element bolt engages. Yellow LED on the control unit is turned on. The
red and green LEDs on the reader light up. The reader buzzer sounds for 5 seconds.
2. Remove the jumper from B3 on the control unit.
The SPE blocking element bolt disengages. The LEDs on the control unit and the reader
go out.
3. Repeat steps 1 - 2 with the door closed to check the precise insertion of the SPE blocking e-
lement's bolt into the bolt-hole.
4. Plug the jumper back into B1 on the control unit once you have completed the function test.
The yellow LED on the control unit's circuit board indicates the system's status as follows:
LED
Status
Off
System is OK
1 flash
Bolt
or disengage.
Required action
None
Switch the power supply off and then back on.
Replace the control unit if the LED is still acti-
vated.
Required action
None
will
not
engage
Check the SPE blocking element and the
bolt-hole for correct installation and electrical
connection.
Repeat the test.