Omron CS1W-SCU21 Operation Manual page 497

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

V600/V620 ID Controller Protocol
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Note If L (management of number of write times) is designated by processing designation, management of
number of write times for Data Carrier of EEPROM is performed.
Control (Sequence No. 541 (Hex 021D))
This sequence performs I/O operations or I/O reads.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
478
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Unit No. (2 digits BCD)
+2
R/W Head CH No.
(1 digit BCD)
+3
Processing designation
(2 digits Hex)
+4
Leading address of check
object
(4 digits Hex)
+5
Number of check block bytes
(2 digits Hex)
Number of receive data words
+0
+1
(Undefined)
Completion code
Offset
Contents (data format)
+0
Number of receive data
words (4 digits Hex)
+1
Completion code
(2 digits Hex)
Number of send data words
+0
(Undefined)
+1
Unit No.
+2
(Undefined)
OUT1 operation OUT2 operation
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Unit No. (2 digits BCD)
+2
OUT1 operation (1 digit BCD)
OUT2 operation (1 digit BCD)
Data
0006 (fixed)
00 to 07 (CD1D)
00 to 15 (CA2A)
R/W Head CH 1 designation:1
R/W Head CH 2 designation:2
The CD1D must be set to 1.
Verification:
43 (C)
Calculation:
4B (K)
Management of number of write times: 4C (L)
0000 to FFFF
(If management of number of write times is desig-
###
###
nated, H'
0 to H'
5 or H'
###
D)
If verification, calculation is designated:
03 to FF (set 00 for 256 bytes)
If management of number of write times is designated:
00 to FF
Data
0002 (fixed)
(Verification, calculation designation)
00: Normal completion for calculation processing
75: Data in normal condition for verification process-
ing
76: Error Data alarm for verification processing
(If management of number of write times is desig-
nated)
75: Number of write times is under those which is
specified
76: alarm for number of write times is over those
which is specified.
0003 (fixed)
00 to 07 (CD1D)
0: No operation
1: turned ON
2: turned OFF
0: No operation
1: turned ON
2: turned OFF
Appendix M
###
8 to H'
Data

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-scu41

Table of Contents