Omron CS1W-SCU21 Operation Manual page 380

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

K3T# Intelligent Signal Processor Protocol
Write Set Value (by Unit Number) (Sequence No. 302 (Hex 012E))
This sequence writes each set value (HH, H, L, LL).
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Set Value HH (Continuous Units) (Sequence No. 303 (Hex
012F))
This sequence writes set value HH for continuous units.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
+0
Number of send data words
+1
Number of units
(Undefined)
Relevant unit No.
+2
+3
Operand
+4
Set value
(Undefined)
+5
~
+122
(Undefined)
Relevant unit No.
+123
Operand
+124
Set value
+125
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Number of units
(4 digits Hex)
+2
Relevant unit No.
(2 digits BCD)
+3
Operand
(ASCII 2 characters)
+4 to +5 Set value
(5 digits BCD)
+124 to
Set value
+125
(5 digits BCD)
+0
Number of send data words
+1
Number of units
+2
Set value
(Undefined)
+3
~
Set value
+64
(Undefined)
+65
Set value
~
Set value
0006 to 007E (6 to 126 decimal)
0001 to 001F (1 to 31 decimal)
00 to 99
4848 ("HH"),
4820 ("H"),
00000 to 99999
Negative sign: F (5th digit in BCD)
Example 12345
2345
+4
0001
+5
Same as above
Set value
~
Set value
Appendix I
Data
4C4C ("LL")
4C20 ("L")
Example –1234
+4
1234
+5
000F
361

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-scu41

Table of Contents