Omron CS1W-SCU21 Operation Manual page 383

Hide thumbs Also See for CS1W-SCU21:
Table of Contents

Advertisement

K3T# Intelligent Signal Processor Protocol
Write Set Value HH with Bank (Continuous Units)
(Sequence No. 308 (Hex 0134))
This sequence writes set value HH of a bank not in use for continuous units.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Write Set Value H with Bank (Continuous Units)
(Sequence No. 309 (Hex 0135))
This sequence writes set value H of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value L with Bank (Continuous Units)
(Sequence No. 310 (Hex 0136))
This sequence writes set value L of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
Write Set Value LL with Bank (Continuous Units)
(Sequence No. 311 (Hex 0137))
This sequence writes set value LL of a bank not in use for continuous units. The word allocation is identical to
that of sequence No. 308 (Write Set Value HH with Bank (Continuous Units)).
364
+0
Number of send data words
+1
Number of units
+2
(Undefined)
+3
Set value
(Undefined)
+4
~
+95
(Undefined)
+96
Set value
(Undefined)
+97
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Number of units
(4 digits Hex)
+2
Bank No.
(2 digits BCD)
+3 to +4 Set value
(5 digits BCD)
+96 to
Set value
+97
(5 digits BCD)
Bank No.
Set value
~
Bank No.
Set value
0005 to 0062 (5 to 98 decimal)
0001 to 0020 (1 to 32 decimal)
01 to 04
00000 to 99999
Negative sign: F (5th digit in BCD)
Example 12345
+2
2345
+3
0001
Same as above
Appendix I
Data
Example –1234
+2
1234
+3
000F