3Z4L Laser Micrometer Protocol
Sequence
No.
416 (01A0)
Statistic processing execution (3000-series)
417 (01A1)
Statistic processing non-execution (3000-series)
418 (01A2)
All statistic memory clear (3000-series)
419 (01A3)
Statistic memory clear (3000-series)
420 (01A4)
Statistic result request (3000-series)
421 (01A5)
Memory switch set 1 (3000-series)
422 (01A6)
Memory switch set 2 (3000-series)
423 (01A7)
Simple AVG times set (3000-series)
424 (01A8)
AVG move interval set (3000-series)
425 (01A9)
AVG move (H) times set (3000-series)
426 (01AA)
AVG move (L) times set (3000-series)
427 (01AB)
Automatic detection set (3000-series)
428 (01AC)
Automatic detection release (3000-series)
429 (01AD)
Automatic detection list request (3000-series)
430 (01AE)
3Z4L initialize (3000-series)
431 (01AF)
Measurement condition set (4000-series)
432 (01B0)
Measurement condition release (4000-series)
433 (01B1)
Measurement condition list request (4000-series)
434 (01B2)
Single run measurement start (4000-series)
435 (01B3)
Deflection measurement start (4000-series)
436 (01B4)
Continuous measurement start (scan) (4000-series)
437 (01B5)
Continuous measurement start (interrupt) (4000-series)
438 (01B6)
Measurement termination (4000-series)
439 (01B7)
Data request (4000-series)
440 (01B8)
Forced positive zero (4000-series)
441 (01B9)
Forced negative zero (4000-series)
442 (01BA)
Forced zero release (4000-series)
443 (01BB)
3Z4L initialize (4000-series)
444 (01BC)
General-purpose command 1
445 (01BD)
General-purpose command 2
446 (01BE)
High calibration set
447 (01BF)
Low calibration set
Note 1. *Normal responses will be returned for these sequences for 5000-series and 6000-series Laser Mi-
crometers, but no processing will be performed.
2. *This sequence will be processed the same as sequence No. 425 AVG move (H) times set for 5000-
series Laser Micrometers.
3. *Memory switch settings will be ignored for these sequences for 5000-series and 6000-series Laser
Micrometers.
4. *This sequence will be processed the same as sequence No. 411 Zero run measurement start for
5000-series Laser Micrometers.
396
Communications sequence name
Appendix K
Operation
5000 Series
6000 Series
Yes
Yes
Yes
Yes
No
*1
No
*1
No
Yes
Yes
Yes
2
Yes*
No
Yes
Yes
*3
Yes
No
No
No
Yes
*4
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
*3
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
*1
No
*1
No
Yes
Yes
Yes
No
No
Yes
Yes
*3
Yes
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
*3
Yes
Yes
Yes
No
No