Visual Inspection System Protocol
General-purpose Command (Send/Receive) (Sequence No. 495
(Hex 01EF))
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is
automatically attached to the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
The reception data is stored in the reception data words without the delimiter (CR+LF),
Receive data
storage words
Note 1. The processing depends on the command.
2. For a command without a response, use sequence #495.
+0
Number of send data words
+1
Command length
+2
Command
(Undefined)
~
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Command length (4 digits Hex)
+2 to
Command (ASCII)
+0
Number of receive data words
+1
Command length
+2
Command
(Undefined)
~
Offset
Contents (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Command length (4 digits Hex)
+2 to
Command (ASCII)
~
0003 to 00FA (3 to 250 decimal)
0001 to 01F0 (1 to 496 decimal)
Specify ASCII data.
~
0003 to 00FA (3 to 250 decimal)
0001 to 01F0 (1 to 496 decimal)
ASCII data is returned.